Installation
8
Using a Swivel Flanged Coupling
To couple the swivel flange with a flanged RF transmission line, use an appro-
priate coupling kit. Refer to Figure 5 while following the instructions.
Figure 5 Swivel Flanged Coupling
1. Insert the center bullet.
2. Push it in until it is fully seated.
3. Connect the coaxial input in a straight line
4. Push carefully on the center conductor to close.
Note:
The swivel flange on the load makes connection independent
of the orientation of the fixed flange on the coaxial input outer conductor.
5. Insert the bolt sets and tighten evenly all around to transmission line
manufacturer’s recommended torque.
Note:
Use all of the bolts.
Using a Unflanged Coupling
To couple the unflanged connector with an unflanged RF line, use an appro-
priate coupling kit. Refer to Figure 7 while following the instructions.
Figure 6 Unflanged Coupling
1. Insert the center bullet
2. Push until it sets the midpoint nibs.
3. Position the outer sleeve, with clamping bands, over the input connector.
4. Set the transmission line snugly against the coupling stops.
5. Position the clamping bands evenly about 3/4” from the ends of the sleeve.
6. Tighten the clamping bands.
BOLT
BULLET
LOAD
RF COAXIAL LINE
RF COAXIAL
LINE
CLAMPING
BANDS
CONNECTOR
SLEEVE
BULLET
LOAD