33
Chapter 5
Fault Location Mode
This measurement identifies the position of impedance
discontinuities (faults) within the antenna/feeder
system. The measurement results are displayed on an
x-y graph. Distance from the Site Analyzer is shown
on the x-axis, while relative magnitude of the
discontinuity is shown on the y-axis.
Set the frequency span, cable type, and calibrate the
Site Analyzer before taking any readings.
Press the
Mode key
Press from
Select Mode
0.0
Meters
18.2
Fault Location Mode
Calibration: Full
1.70
1.00
V
S
W
R
Save/
Recall
Auto
Scale
Limit
Test On
Run
Содержание Site Analyzer SA-2000
Страница 2: ...This page is not blank...
Страница 14: ...Bird Site Analyzer 4 Component Description 1 2 3 4 5 6 7 8 9...
Страница 24: ...Bird Site Analyzer 14...
Страница 42: ...Bird Site Analyzer 32...
Страница 80: ...Bird Site Analyzer 70...
Страница 84: ...Bird Site Analyzer 74 Press to sort traces Press to complete trace labeling...
Страница 90: ...Bird Site Analyzer 80...
Страница 100: ...Bird Site Analyzer 90...
Страница 106: ...Bird Site Analyzer 96...
Страница 108: ...Bird Site Analyzer 98...