Introduction
4
Ethernet Measurement Interface
The 4042E sensor displays measurement information on a Web UI. Using a web
browser, enter the
for the 4042E to display the web page.
Table view displays the composite Forward, Reflected, and VSWR measurements
and the same measurements for each configured channel. See
Figure 4 Web UI, Table View Measurement Display
Ethernet IP Address
Each 4042E leaves the factory with the same default IP Address.
Default IP Address:
192.168.3.200
To change the IP address see
.
PTT
PTT is used to prevent false alarms during periods when the transmitter is not
transmitting. PTT disables alarm detection when the transmitter is off. Alarm
functions will only be possible when the transmit button is engaged.
PTT may be set to normally open or normally closed logic. The PTT terminals
must be in the correct logic state for PTT to operate correctly.
Note:
PTT input is a passive connection and requires a 5V TTL
signal to operate.