Page 4
Configuration of individual parameters with «Reglobeam» remote control
* Factory setting
Parameter
Key code
Level
Short description
Request access code
C+9
Display 1
Display 2
Code saved
No Code
Set Code
Enter Code
Delete Code
C+9
XXXX+C
XXXX+C
9999+C
Number from 1111–9998 and confirm with C
Enter selected code and confirm with C
Code deleted
Address settings
F+8
interrogate target address
5–7
setting address 5–7
9
read in address from DIP-Switch
Enhanced function
C
1–8
See table of enhanced functions
1
2.0 – 2.4 m
Mounting height
F+4
2
3
4*
5
6
7
2.5 – 2.9 m
3.0 – 3.9 m
4.0 – 4.9 m
5.0 – 5.9 m
6.0 – 6.9 m
7.0 m
Field size
D
1–3
4–6*
7–9
Small
Medium
Large
Relay hold interval
F+1
1
2
3
0.2 s
0.5 s
1.0 s
4*
2.0 s
5
5.0 s
Direction recognition
E+1
1*
2
Forwards
Backwards
3
Forwards and backwards
Relay parameterisation
E+2
1*
2
3
4
5
6
7
8
Standard industrial door, differentiation between people and vehicles
Standard industrial door, people suppression
Standard industrial door, vehicle suppression
Standard industrial door, people and vehicles, same output
Standard industrial door, people and vehicles, outputs with direction segregation
High-speed industrial door, people suppression
High-speed industrial door, people and vehicles, same output
High-speed industrial door, people and vehicles, outputs with direction segregation
CTM
Crossing traffic masking
F+5
1*
Off
2–3
4–6
7–9
Low
Medium
High
Wide field
B
1
2*
On
Off
Slow Motion Detection
F+3
1*
Off
2
3
4
5
0.5 s
1.0 s
1.5 s
2.0 s
Decreasing sensitivity
6
7
8
9
0.5 s
1.0 s
1.5 s
2.0 s
Constant sensitivity
SMD field size
F+7
1*–3
Small
4–6
7–9
Medium
Large
Digital filter function
F+6
1
2*
On
Off
Avoidance of false tripping by fluorescent tubes
Manual industrial door opening
A
1
2
3
Switch off both relays
Switch on relay 1
Switch on relay 2
Exit configuration mode
A
4
Reset
A
9
Reinitialise