BCP-760
Operation Guide
Page 19 of 31
DATA LENGTH
4
DATA TYPE
NUMERIC
DEVICE TYPE
KEY ONLY
DATA RECORD DEFINITION
Category
Setting
BETWEEN FIELD
Append screen
FIELD DELIMITER
,
RECORD FELIMITER
CR
DATE STAMP FIELD
NONE
TIME STAMP FIELD
NONE
FIELD DELAY
0
1.8.1.13
POWER or ON-OFF
The BCP-760 provides system power on/off feature. Once 5 is selected, user can define the 1.)RESUME,
2.)AUTO OFF, 3.)ALARM
1.RESUME
When the Resume function is enabled, the BCP-760 will resume program execution from the
last turn-off point when it is powered on again. The default setting is ON (enabled).
1. Press 1 (1.RESUME)
2.
At the STATUS SETUP Menu, use the [
] key to select between RESUME ON (enable
Recovery) and RESUME OFF (disable recovery)
3. Press [ENT] to complete the setting
2.AUTO OFF Use the [
] key to set auto-off timeout from 1 to 9 minutes. The BCP-760 will turn itself off
automatically after being idle for the time period specified in the
AUTO OFF
setting. The default
setting of
AUTO OFF
is 5 minutes. The auto-off feature is disabled when set to 0 minutes.
A smart power management system is built in BCP-760 hardware and software to conserve
battery power. The BCP-760 power transition flow is as follows:
POWER
ON
ACTIVE
STAND
POWER
FAILURE
SHUT
DOWN
BY
press [PWR]
wait on
keyin/scan
key in
bar code scan
RS232 input
press [PWR] (switch off)
press [PWR]
program running
NMI
(switch off)
(switch on)
Auto-off timeout
OR
call INT 22H
♦
Active
All system hardware is activated in Active mode. The system will enter Stand-by
mode if it waits on input or call INT 22H.
♦
Stand by
In the Stand-by mode, if a key is depressed, a bar code or RS-232 input occurs
the BCP-760 will return to Active mode. Otherwise, the portable terminal will
enter Shutdown mode if the BCP-760 has been idle for the specified timeout
period as set in
AUTO OFF
.
♦
Shut Down In Shutdown mode, the main power is cut off from the BCP-760 excluding its
RAM and Real Time Clock.