NOTE

The ozone generator should be installed in a clean and dry place with good air circulation.

To extend the service life, please keep the ozone generator clean and keep it far from water and
moisture.

Some components and parts indicated in this user manual  and graphic illustration are available to
purchase separately. For details please refer to the user manual.

The right to revise parameters and specifications in this manual is reserved by our company. We
reserve the right to improve and update our user manuals. All changes will be presented in new user
manual editions, however not announced in advance.

All the illustrations in this manual are for better explanation and the images may differ from the
ozone generator purchased. Where there is deviation from the description and the ozone generator,
it should be subject to the ozone generator.

WARNING

To avoid high-voltage injury, the external cabinet must be opened by a professional operator and
cannot be opened while the ozone generator is running.

IMPORTANT INFORMATION

Do not use this product near high-precise electronic equipment, as electric waves may cause
mal-operation of the high precise electronic equipment and other issues.

Special attention should be paid to the equipment as follows;

Hearing aid, pacemaker and other electro-medical equipment, fire detector, other high-precise
automatic control equipment.

Do not dismantle or reconstruct this product, otherwise it may lead to damage, electrical leakage and
faults in the electrical circuit.

High moisture, penetration of water and other liquids to the generator may lead to damage, electrical
leakage and faults in the electrical circuit.

To avoid damage on the surface of the equipment, volatile solution or organic solvent should not be
used to clean the ozone generator.

To eliminate potential fire damage, qualified special grounding cable, reliable grounding and wire
with enough capacity are required. Qualified or trained maintenance personnel to be trained on the
use and maintenance of the ozone generator.

While the ozone generator is running, workers are not permitted to work in a space with high
concentrations of Ozone. To work in a space with over-standard Ozone concentrations, protective
measures must be taken.

Keep in mind that maintenance can only be carried out when the equipment is off power and air
pressure is completely released.

Make sure the lines of electricity, gas, water, inlet and outlet air pipes are properly connected.

OPERATION ENVIRONMENT OF THE OZONE GENERATOR

There shall be no flammable and explosive gas and conductive powder dusts in the room

Not permitted to install the ozone generator in a place where alkaline air is easy to leak or with risk of
explosion.

2

Содержание BASIC SS 10G

Страница 1: ...BIOZONE BASIC SS 10G USER MANUAL OZ 3G OZ 5G OZ 7G OZ 10G OZ 15G Before installing and operating please read the user manual carefully Please keep this user manual for future reference 1...

Страница 2: ...Hearing aid pacemaker and other electro medical equipment fire detector other high precise automatic control equipment Do not dismantle or reconstruct this product otherwise it may lead to damage ele...

Страница 3: ...ose natural disasters beyond our control or responsibility such as earthquake fire flood or losses caused by behaviour or accident including misuse by the user intentionally or unexpectedly in these a...

Страница 4: ...T AIR DRYING AND OXYGEN APPARATUS 11 OPERATION AND CONNECTION METHOD OF OZONE GENERATOR WITH AIR DRYING OR OXYGEN APPARATUS 11 Notice items while using silica gel drying tank 11 Ozone generator with i...

Страница 5: ...dized organics THM with carcinogenicity if a polluted water source is treated by chlorinating Using ozone in treatment there will be no secondary pollutant Sewage treatment includes civil sewage indus...

Страница 6: ...an effectively kill viruses bacteria mould and other microbes depending on its oxidation capacity Like an antiseptic it will cause certain physiological reactions and even damage but the amount is muc...

Страница 7: ...ry air source input g h 2 5 3 5 3 5 5 7 5 Cooling style Air cooled maximum ozone concentration g m3 Oxygen source 25 50 Dry Air source 5 15 L x W x H mm 345 x 215 x 520 345 x 215 x 580 Weight Kg 11 12...

Страница 8: ...switch for whole equipment 10 Power line 3 Ozone regulating turn button 11 Fuse tray 5A fuse 4 Ammeter 12 Fan fence net Regular maintenance clean once every 1 3 months 5 Ozone aworking indicating ligh...

Страница 9: ...delivery is for choice INTERNAL STRUCTURE Fig 5 Internal structure Table 4 Illustration to internal structure 16 Regulation resistance for current regulating 20 Circuit board 17 Inlet pipe to ozone g...

Страница 10: ...r or after sale service department of our company If an unclean air source is input or the equipment has been working for more than 12 months there may be dust attached on the surface of the discharge...

Страница 11: ...ng hours if the air is dry the heating interval can be 24 working hours or longer If the ozone generator has not worked for a long time 30days it needs heating and drying one hour before the ozone gen...

Страница 12: ...dryer indicated in the figure can also be replaced by other dryers the drying tank needs to be purchased separately Connection of silica gel drying tank Condition permitting silica gel drying tank sho...

Страница 13: ...inspections are completed if there are still problems unsolved or cases related with maintenance please contact the local distributor or post sale service department of our Power connection failure Ch...

Страница 14: ...mpany may charge for the repairing materials Product damages due to a high humidity working environment or oxygen concentrator flooded by water Product damages due to unauthorized operation unless ins...

Страница 15: ...15...

Страница 16: ...16...

Отзывы: