Table 5 Instruction of product with heating and drying tube to internal structure
24 Drying tube
25
Temperature control thermostat, stop
heating while the temperature is higher
than 60C
26
Switch for heating
The ozone generator stops while heating
27
Heating tube has the specification of
9.5mm*200mm capacity <400w and
220V 50/60Hz
Instruction for heating and drying tube
●
There may be water, oil and dust in the air. If they are not eliminated, it will influence the ozone
capacity and lifespan of the ozone generator
●
The product with internal heating and drying tube is easy to operate and it can supply the dry air
resource in an economic way
●
Product instruction with internal heating and drying tube (See image 10)
During the ozone generator operating, the water and other undesired substances in the air will be absorbed
by the drying material in the drying tube, then evaporated to the air through heating the heating tube.
Specific usage as follows:
●
The heating interval is every 12 working hours; if the air is dry, the heating interval can be 24 working
hours or longer.
●
If the ozone generator has not worked for a long time (30days) it needs heating and drying one hour
before the ozone generator works.
●
Heating the drying tube is required after the ozone generator works for 12hous. Turn off the whole
ozone generator and follow the below steps:
●
Pull off the air pipe connected with outlet 7, let the gas go out through outlet 7 into the air.
●
First, turn on the heating switch which is on position 26
●
Then, turn on power switch 1 of the whole machine and switch 2 of the air pump (at this time, the
ozone generator stops working). Temperature controller 25 will disconnect the power while heating
tube 27 reaches a set temperature after heating for several minutes.
●
After heating for about 1 hour, the power switch 1 of the whole machine and switch 2 of the air pump
are on the “off” position; the heating switch 26 is on the “off” position (see chart 5) and the heating
work stops.
●
Connect the pipe of air output 7, and the dry air of outlet 7 can lead to the oxygen inlet 9 of the
ozone generator.
●
The drying material should be changed regularly. It is better to replace it every 6-12 months.