The scope of the user manual

The user manual is for our Aquazone 200g - 400g series products.

Purpose of the user manual

Served as the instruction for operation personnel

Knowledge required for understanding the user manual

You will have a better understanding of the user manual if you have a mechanical and
electrical background, and will qualify for the equipment maintenance.

SAFETY NOTES

SAFETY PRECAUTIONS

Qualified special grounding cable, reliable grounding, and safety grounding are required, otherwise
electric shock and other dangers may occur. The grounding cable must be connected to the
dedicated grounding device of the building; otherwise installation personnel should refuse to install
the equipment. If there is no dedicated grounding device, it should be installed by professional
technicians (the grounding cable must not connect to the gas or water pipe, lightning rod/conductor,
or telephone cable)!

Ozone is a strong oxidising gas, and the ozone system must shut down when there is Ozone
leakage. Then check the leakage point, and repair it before restarting the system. Otherwise, ozone
leakage will lead to equipment oxidised and is harmful to staff around.

Staff is prohibited to enter the space when the machine is being used for space sterilisation. In other
words, business time and sterilisation time should be staggered. People are allowed to enter after
sterilisation has been finished for two hours

Loaded power should be configured with an isolator especially in high moisture locations. Otherwise,
it may cause fire.

The equipment cannot be installed in areas with high moisture or smoke, to avoid potential danger.

Unauthorised disassembly, movement and reassembly are prohibited.

The equipment can only be installed by qualified personnel.

Improper installation may lead to ozone leakage, electricity short circuit and fire.

The equipment should be installed in a place where it is convenient for maintenance. Please refer to
the relevant chapter for maintenance. Users should supervise the installation personnel to read the
user manual carefully, arrange the installation order, and fully prepare before installation.

The equipment must not be installed in an area with risk of Ammonia leakage or explosion.

IMPORTANT NOTES

Installation personnel must be qualified technicians and maintenance personnel must be trained before
maintenance.

The equipment must prevent water from going into the inside.

2

Содержание AQUAZONE 200G

Страница 1: ...d ventilation To prevent backflow water gas liquid mixing connections should be installed strictly according to this guide At least allow 5 seconds to turn on and off the ozone generator Please keep t...

Страница 2: ...4 1 CONTROL PANEL DESCRIPTION 6 300G INTERFACE 8 200G 400G AND 600G INTERFACE TWO SETS MODULAR DESIGN 9 4 20MA ANALOG SIGNAL RECEIVING PORT 10 INSTALLATION AND MAINTENANCE 11 INSTALLATION PLACE REQUI...

Страница 3: ...ill lead to equipment oxidised and is harmful to staff around Staff is prohibited to enter the space when the machine is being used for space sterilisation In other words business time and sterilisati...

Страница 4: ...s to be in good ventilation and install an exhaust fan if necessary The ambient humidity must not be higher than 90 otherwise there will be water drops inside the equipment causing electricity leakage...

Страница 5: ...ated power supply unit which has comprehensive control and protection The modular design has also made it quite simple for maintenance Anti moisture HV transformer design The HV transformer is sealed...

Страница 6: ...design 3 5A each set Two sets modular design Power 2 5 3 5 4 8 7 0 Working pressure 0 2bar Cooling water flow 25 6LPM 10LPM 12LPM 20LPM Ambient temperature 40 Ambient humidity 70 Cooling water input...

Страница 7: ...the specification Equipment overcurrent protection This feature is reserved IGBT overcurrent protection This feature is reserved High voltage transformer overheat protection When the indicator lights...

Страница 8: ...7...

Страница 9: ...water outlet Outlet water temperature should be lower than body temperature feeling cool otherwise a higher flow is required Ozone outlet A non returning check valve and backflow water prevention dev...

Страница 10: ...200G 400G AND 600G INTERFACE TWO SETS MODULAR DESIGN 9...

Страница 11: ...4 20MA ANALOG SIGNAL RECEIVING PORT 10...

Страница 12: ...xygen Cooling water pipe DN20 PVC is suggested The inner diameter needs to be over 10mm Ozone output pipe 304 316 stainless steel pipe or PTFE pipe is suggested The inner diameter needs to be over 15m...

Страница 13: ...mable material accessories and the L series products from Biozone are warranted for one year from the date of purchasing The following occasions are excluded from the warranty and Biozone may charge f...

Страница 14: ...net Clean replace Cycling clean Dry moisture on high voltage parts Clean Maintain during humid season Inner side of internal and external electrode Clean Regular clean when used in beverage and food...

Страница 15: ...se cooling water flow 5 Disconnect the 4 20mA signal and check 6 Replace potentiometer 7 Replace the digital power supply unit 4 Low ozone output low current over 0 5A but lower than rating current Ad...

Страница 16: ...SU output cables Check HV transformer and the connections Clean the cooling channels replace cooling fan Lower ambient temperature E11 PSU IGBT over heated Cooling fan channel blocked or cooling fan i...