Equipment side interface description
○
Flow meter
○
Ozone generator input gas flow display
●
Gas source input
○
Either oxygen input or air input
●
Cooling water inlet
○
It is advised to use tap water for cooling water. If use other water or circulating water,
Polypropylene (PP) cotton water filter should be installed before cooling water inlet,
otherwise impurities in the water or metal oxides will lead to insufficient heat dissipation.
●
Cooling water outlet
○
Outlet water temperature should be lower than body temperature (feeling cool), otherwise, a
higher flow is required.
●
Ozone outlet
○
A non-returning check valve and backflow water prevention device have to be installed
between the ozone outlet and the venturi injection device in the water treatment application,
preventing back flow water from going into the equipment!
●
4 ~ 20mA signal receiving port
○
Automatically adjust the amount of ozone when received 4-20mA analog signal
●
Power cable
○
220V 50Hz and the power must come with the ground cable, otherwise may lead to electric
leakage when the equipment gets wet!
300G INTERFACE
8
Содержание AQUAZONE 200G
Страница 8: ...7...
Страница 10: ...200G 400G AND 600G INTERFACE TWO SETS MODULAR DESIGN 9...
Страница 11: ...4 20MA ANALOG SIGNAL RECEIVING PORT 10...
Страница 17: ...CONTACT US 16...