7
Prox-E Installation Guide v1.2|10.2018|en
11
IN1
Discrete input 1
Enter/exit buttons, door sensors
12
IN1+
Discrete input «+»
Enter/exit buttons, door sensors
13
IN2
Discrete input 2
Enter/exit buttons, door sensors
14
IN2+
Discrete input «+»
Enter/exit buttons, door sensors
15
IN3
Discrete input 3
Enter/exit buttons, door sensors
16
IN4
Discrete input 4
Enter/exit buttons, door sensors
17
VC0
Reader power supply 12V
Reader power input
18
GND
Ground
Reader ground
19
WI00
Wiegand input 00
Reader, wiegand 00
20
WI01
Wiegand input 01
Reader, wiegand 01
21
SP0
Reader speaker input
Reader, speaker output
22
L_G0
Reader green indicator input
Reader, green indicator output
23
L_R0
Reader red indicator input
Reader, red indicator output
24
WI01
Wiegand input 01
Reader, wiegand 00
25
WI11
Wiegand input 11
Reader, wiegand 01
26
SP1
Reader speaker input
Reader, speaker output
27
L_G1
Reader green indicator input
Reader, green indicator output
28
L_R1
Reader red indicator input
Reader, red indicator output
29
VC1
Reader power supply 12V
Reader power input
30
GND
Ground
Reader ground
31
RD+
485+
BS-RD, Biosmart Mini 485+
32
RD-
485-
BS-RD, Biosmart Mini 485-
33
IN6+
Discrete input 6 «+»
Enter/exit buttons, door sensors
34
IN6
Discrete input 6
Enter/exit buttons, door sensors
35
IN5+
Discrete input 5«+»
Enter/exit buttons, door sensors
36
IN5
Discrete input 5
Enter/exit buttons, door sensors
37
W00
Wiegand output 00
External controller wiegand input 00
38
W01
Wiegand output 01
External controller wiegand input 01
39
+485
RS-485 interface «+»
BCR (Zflex) Relay control module 485 +
40
-485
RS-485 interface «-»
BCR (Zflex) Relay control module 485 -