U
N I T
P
A R A M E T E R
S
E T T I N G S
55
© Copyright 2002, Bioscrypt Inc. All rights reserved.
Quick COMM Test
The button will perform a quick COMM TEST with the device identified by the
displayed Current COMM settings. The test will flash the LED each color then
sound the buzzer.
Biometric Verification
This option allows the user to turn biometric verification on and off. Check or
uncheck this option and press the SET button. Unchecking the box will cause the
unit to bypass the core fingerprint authentication (i.e., no finger required) and
allows for Wiegand pass-thru authentication alone.
Turning this off will result in
a less secure system and is not recommended!
The user assumes all risk
associated with disabling biometrics.
Finger Detect (V-PASS only!)
This section will show the current setting of the Auto Finger Detect function of the
V-PASS product. The user can select the option desired and press the SET
button to modify the setting on the current unit. This section is disabled when the
current unit is not a V-PASS.
Wiegand Settings
This section allows you to send coded messages to your Wiegand device (where
applicable). Pressing the SET button will transfer all WIEGAND SETTINGS
values at once.
Wiegand FORMAT
This section allows you to select the desired Wiegand format for both INPUT and
OUTPUT. 26-bit Standard is the default format. Other custom formats are
available and can be selected using the dropdown box.
NOTE:
the format for BOTH INPUT and OUTPUT will be the same
FailString Out
When you check the
FailString Out
box, whatever code you type into the
Failure
Code
field will be sent to the Wiegand device when a failed authorization occurs.
The string is numeric and ranges from 0 to 65535.
If the box is unchecked then no string will be sent when a verification fails.
Alt Site Code
When you check the
Alt Site Code
box, whatever code you type in the
Site Code
field will override the site code on all cards used on the unit.