![bioscrypt V-PASS Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/bioscrypt/v-pass/v-pass_operation-manual_2755005040.webp)
T
E M P L A T E
M
A N A G E R
39
© Copyright 2002, Bioscrypt Inc. All rights reserved.
2
Click the Enroll button.
The light on the VeriProx will glow amber requesting the enrollee to place a
finger on the sensor. Nestle the Ridgelock into the first joint line on the finger.
The finger may be removed when the amber light goes out and VeriAdmin
instructs you to remove the finger.
3
The light will glow green and the unit will beep once to acknowledge that the
fingerprint has been captured.
If a finger is not placed within ten seconds, the light will glow red and the unit
will time out. Similarly the light will glow red if the unit was unable to image the
fingerprint. (See the appendix for a discussion of proper enrollment).
4
On the Quick Enrollment screen, the
Quantity
and
Content
fields each will
display from one to five stars indicating how well the print was read. In
addition, a sample of the print will appear in the left center of the screen.
A rating of at least three stars in each field is recommended.
5
If you are unsatisfied with the read, repeat steps 3 and 4 above.
6
Press the Accept button to continue with the enrollment.
At this point, the Edit Template window will open (see page 37). Complete the
Username
field, identify the finger that was scanned, and select a S
ecurity
Threshold
. You may change the index if you are enrolling more than one
finger under the same ID, but normally this should be zero.
7
Select the user type. This is either
User ID
,
Enroll ID
, or
Delete ID
depending
on the type of card you are enrolling. The default is
User ID
.
Note:
remember that if the card number already has been designated as one
of the three types, then any subsequent templates assigned to the card must
be of the same type.
Note:
if you have more than one unit networked together, it is recommended that
you broadcast the new enrollment to the other units at this time.
Delete Templates
Use this option to delete one or more templates from a single unit (if you are in a
networked environment, see the
BROADCAST PARAMETERS
section).
Select the appropriate ID number(s) in the
Templates
window and click the Delete
button (recall that you can use the Shift and Ctrl keys to select multiple templates).
Note:
You WILL NOT receive a warning when you are deleting
templates unless you are deleting all of them. Therefore, be