Bioscience Ampulmatic-10 Purge Gas Injector Скачать руководство пользователя страница 4

Statement of Warranty 

 

The Ampulmatic

®

-10 Liquid Filler accessory is warranted against faulty workmanship or the use of 

defective materials for a period of 365 days from the date of shipment.  This warranty is the only 

warranty made by Bioscience, Inc. (Manufacturer) and is in lieu of all other warranties, expressed 

or  implied,  except  as  to  title  and  can  be  amended  only  by  a  written  instrument  signed  by  the 

Manufacturer. The Manufacturer provides no warranty to the Customer, either express or implied 

nor  for  title.    Manufacturer  further  disclaims  any  warranty  of  merchantability  or  fitness  for  a 

particular purpose in connection with the customer’s purchase of units of any Product under this 

agreement.   The  liability of the  Manufacturer under this warranty is limited solely to replacing, 

repairing, or issuing credit (at Manufa

cturer’s discretion) for any device which is returned by the 

customer  during  the  period  provided  for  above,  provided  that  (a)  Manufacturer’s  product  is 

returned  properly  packaged  in  the  package  made  per  specifications  equal  to  or  better  than 

Manufacturer’s

 original carton specifications, (b) Manufacturer is promptly notified in writing upon 

discovery  of  such  defects  by  customer,  and  customer  obtains  return  authorization  from 
Manufacturer to ship the unit, (c) the defective unit is returned to Manufacturer, transportation 

charges prepaid by customer, (d) warranty card, with date of receipt of product and signed by the 

customer,  is  returned  to  the  Manufacturer  within  30  days  of  purchase,  and  (e)  Manufacturer’s 

examination of such unit shall disclose, to its good faith satisfaction, that such defects have not been 

caused by misuse (including the filling and/or sealing of corrosive materials), neglect, improper 

shipping or installation, repair, alteration, or accident.  In no event shall Manufacturer be liable for 
loss of profits, loss of use, or damages of any kind based upon a claim for breach of warranty. 

 

All claims under this warranty will be made directly to Manufacturer.  Faulty units are to be shipped 

prepaid  to  the  Manufacturer’s  designated  location.    Man

ufacturer  shall  prepay  transportation 

charges when repaired units are returned and bill customer unless the units are found defective 

under this warranty.  Manufacturer shall pay return freight of units found defective under warranty.  

Claims with the freight carrier for damages in shipment shall be made by the party of destination. 

 
For your records, please record:  Ampulmatic-10 Liquid Filler Serial No. _________________   

 

Complete, Detach and Return Within 30 Days of Receipt 

-------------------------------------------------------------------------------------------------------------------------------- 
 

User’s Na

me _________________________ 

User’s Sign

ature ____________________________ 

 
Title_______________________________Ship Date ________________________________ 
 
Company ___________________________ Receipt Date_______________________________ 
 
Address ____________________________ Warranty Received at Bioscience_________________ 
 
 

____________________________ Have you set up your new Liquid Filler? ____________ 

 
Phone ____________  Fax _____________  Have you operated your Liquid Filler?_____________ 
 
Liquid Filler Serial No.  _________________   
 
Comments (Sales, Delivery, Manual, Instructions) 
 

 

2-1 

Содержание Ampulmatic-10 Purge Gas Injector

Страница 1: ...ller Accessory Operation and Maintenance Manual Bioscience Inc 2201 Hangar Place Suite 200 Allentown PA 18109 Phone 484 245 5232 Fax 484 245 5236 bioscience bioscienceinc com www bioscienceinc com Ori...

Страница 2: ...iquid Filler Features 4 1 Unit Specifications 5 1 Setup 5 1 Initial Setup 5 2 Installing the Liquid Filler Syringe 5 4 Installing the Tubing 5 5 Calibrating the Filling Volume 5 6 Final Setup 5 7 Adju...

Страница 3: ...rton and the unit for shipping damage Notify the carrier immediately if damage is found 2 Use the Accessory Check List attached to this manual when unpacking the unit to verify that the complete unit...

Страница 4: ...nufacturer within 30 days of purchase and e Manufacturer s examination of such unit shall disclose to its good faith satisfaction that such defects have not been caused by misuse including the filling...

Страница 5: ...to inject volumes between 1ml and 20ml into each ampule within the cycle time required to flame seal the ampule It was designed with a chemically inert fluid path to accommodate the injection of a wi...

Страница 6: ...10 Liquid Filler Features 3 2 Syringe Solenoid Valve Safety Switch Syringe Clamps Upper Limit Switch Lower Limit Switch Solenoid Luer Lock Black Knob Fasteners 3 Switch Trigger Bracket PTFE Ferrules P...

Страница 7: ...Fluid Path Borosilicate Glass PTFE 316ss Note Corrosive liquids must be tested in advance of filling and sealing for compatibility with the materials of construction of the Ampulmatic 10 base unit an...

Страница 8: ...gas supplies connected and the flame adjustments made and the Purge Gas Injector accessory has been completely set up the Liquid Filler accessory may be set up Reference the Ampulmatic 10 Liquid Fill...

Страница 9: ...the luer lock on the solenoid valve by twisting the syringe clockwise onto the luer lock fitting Do not over tighten Orient the syringe so that the flat edge of the metal end of the syringe barrel is...

Страница 10: ...ger so that it reaches the switch trigger bracket Insert the provided 6 32 screw through the bottom of the switch trigger bracket Straight up and tighten with an allen wrench to grip the plunger of th...

Страница 11: ...ng can be done before the sealing cycle is complete 1 Attach PTFE tubing to the fitting on the right side of the solenoid valve using PTFE ferrules Route the tube through the right hand slot on the ba...

Страница 12: ...in this Manual NOTE The safety shield must be in the down position for the Liquid Filler accessory to operate The unit must be manually restarted every time the safety shield is raised and lowered Tur...

Страница 13: ...rge Gas Injector Head 3 If using only the Liquid Filler Injector Head position it so that injection occurs at least 2 positions prior to flame sealing NOTE Refer to the Purge Gas Accessory Operation a...

Страница 14: ...r can be used to adjust the speed of the syringe by inserting the screwdriver into the Syringe Speed Adjust hole and turning the potentiometer clockwise to increase the speed or counterclockwise to re...

Страница 15: ...ss other than borosilicate will require careful alignment of the accessory filler heads and possible adjustment of the loading of the integrated filler head spring to avoid ampule breakage Soft glass...

Страница 16: ...are free of air bubbles during injection Calibrate and check injection volume Every 10 000 injection cycles or 25 hours of operation or 1 month whichever comes first Remove and inspect syringe Clean s...

Страница 17: ...r liquid injection is connected to appropriate port on Purge Gas Injector accessory Check to make sure safety shield is down and safety switch is triggered on Liquid Filler accessory Check to make sur...

Страница 18: ...See Adjusting Syringe Speed in the Setup section of this manual Check all fluid path connections for air leaks see Fluid line contains air bubbles Check syringe integrity and replace syringe if necess...

Страница 19: ...mp front 270 055 Syringe clamp screws 270 056 Solenoid Valve 270 067 Swagelok SS 28 to OD fitting 270 080 Swagelok SS OD to 1 8 OD fitting 270 089 Swagelok OD Teflon ferrules 270 082 Swagelok 1 8 OD S...

Отзывы: