stopped with hand during operation, the program does not stop and the 

platform motion is automatically resumed after the platform is released. 

4.10.Disconnect the external power supply unit from electric circuit

 to turn off 

the 

unit

.

5

.  Program setting

When  setting  program  parameters  please  mind  that  the  unit  may 

be 

unable  to  operate  properly 

in  reciprocal  and  vibration  modes

  with 

maximum load

. The recommended load is indicated in table 1 on page1

2.

5.1.

Press 

the 

Select

 key (Fig.1/1) to choose the parameter to change (the 

active parameter is flashing). 

5.2. 

Use 

the 

q

 and 

p

 keys (Fig.1/4) to set the necessary value (note: if the key 

is pressed for more that 2 sec the numerical changes quickly).

5.

3

.

Saving  the  program  doesn`t  require  additional  operations:  the 

microprocessor  saves  the  last  parameter  changes  as  the  working 
program automatically.

5.

4

.

The countdown timer is used to control the operation time. The timer can 

be set for the period from 1 min to 24 hours. 

5.

5

.

The  examples  below  show  separate  motion  types  and  their  available 

combinations in cycles. The data 

to the right

 show the possible parameter 

values for each type.

5.

5

.

1. 

Orbital Rotation

Set  the  speed  of  Orbital  rotation  (

1-

100 

rpm), time of Orbital rotation (1 - 

250  sec)  and  time  for  Reciprocal 
motion to zero (OFF).

5.

5

.

2. 

O Reciprocal Rotation

Set

 the speed (1-100 rpm) and time 

(1 - 250 sec) of Orbital rotation. Set 
the turning angle from vertical plane 
(1-90º)  and  time  (1  -  250  sec)  for 
Reciprocal  motion.  Switch  off  the 
V

ibro  motion  (set  the  time  of  Vibro 

motion to 0 (OFF)).

Time (sec.)

o

1-90

o

0-5

1-250

OFF

OFF

Orbital 

(rpm)

Reciprocal

 (deg.)

Vibro

 / pause

o

1-90

o

1-5

1-250

1-250

OFF

Time (sec.)

Orbital 

(rpm)

Reciprocal

 (deg.)

Vibro

 / pause

1-100

1-100

Содержание Bio RS-24

Страница 1: ...Multi Bio RS 24 Programmable rotator for version V 3AW Operating Manual Certificate Medical Biological Research Technologies...

Страница 2: ...Contents 1 Safety precautions 2 General information 3 Getting started 4 Operation 5 Program setting 6 Specifications 7 Maintenance 8 Warranty and Claims 9 Declaration of Conformity Page 2...

Страница 3: ...ing and decontamination methods recommended by the manufacturer Do not make modifications to the design of the unit ELECTRICAL SAFETY Connect only to a power supply with voltage corresponding to that...

Страница 4: ...o run on the borders of reciprocal motion segment It is available only when the reciprocal motion is ON Do not operate the unit if it is faulty or has been installed incorrectly Do not use outside lab...

Страница 5: ...vide increased methodical means to researchers working in the field of modern molecular and cell biology and the developing biodiagnostics technology based on the use of magnetic particles for which u...

Страница 6: ...1 copy Optional accessories PRS 5 12 platform v on request PRS 10 platform w on request PRSC 22 platform x on request PRSC 10 platform y on request PRS 1DP platform z on request 3 3 Set up place the...

Страница 7: ...set and the timer indicator Fig 1 2 shows 0 00 pressing the Run Stop key will cause continuous operation of the rotator until the Run Stop key is pressed again 4 7 If the operation time is set the pla...

Страница 8: ...perations the microprocessor saves the last parameter changes as the working program automatically 5 4 The countdown timer is used to control the operation time The timer can be set for the period fro...

Страница 9: ...time of Reciprocal motion is shorter or equal to the set time of Vibro pause mode the Reciprocal motion mode will be omitted Orbital Pause 5 5 5 Reciprocal Rotation Set the speed 1 100 rpm for Orbital...

Страница 10: ...r performs soft vibration Vibro motion However there is a mode for hard vibration To perform hard vibration set the turning angle of Reciprocal motion to 90 and the angle of Vibro type motion to 1 Har...

Страница 11: ...ation mode Tilt angle range 1 90 increment 1 Time setting range 0 250 sec 6 3 Vibro pause mode Tilt angle range 0 5 increment 1 Time setting range 0 5 sec 6 4 Digital time setting 1 min 24 hours or no...

Страница 12: ...continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice Up to 100 g for platform with rubber clamps or 200 g for platf...

Страница 13: ...your local Biosan representative 7 2 All maintenance and repair operations must be performed only by qualified and specially trained personnel 7 3 Standard ethanol 75 or other cleaning agents recomme...

Страница 14: ...istributor to check availability of extended warranty 8 3 If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the loca...

Страница 15: ...Version 3 03 October 2012 9 Declaration of Conformity...

Страница 16: ......

Отзывы: