Biosan Bio RS-24 Скачать руководство пользователя страница 4

·

Do not operate the unit if it is faulty or has been installed incorrectly.

·

Do not use outside laboratory rooms. 

·

Do not place a load exceeding the maximum load value mentioned in the 

Specifications section of this Manual.

BIOLOGICAL SAFETY

·

It is the user's responsibility to carry out appropriate decontamination if 
hazardous material is spilt on or 

penetrates into 

the equipment.

2

. General Information

Multi  Bio  RS-24 

p

rogrammable  rotator

 

provides:  1)  orbital  rotational 

motion, 2) reciprocal motion, 3) vibro motion of the platform in different planes 
according to the microprocessor protocol. The protocol 

enables making not 

only  programs  that  include  mixing  motion  of  one  particular  type,  but  also 
programs that alternate mixing motions of different types cyclically.

 

There are options for setting:

1) 

Speed and time of ordinary 

R

OTATIONAL

 M

OTION

 

(360º)

of the platform for a time period 0 - 250 sec, 

or non-stop

 with the speed of 1 - 100 rpm.

2) 

Segment of 

R

ECI

PRO

CAL

 M

OTION

 when

the direction of platform rotational

 motion

 

from 

the vertical plane is changing in turns within 
the limits of the set segment (turning angle 1 - 
90º for a time period 0 - 250 sec, or non-stop);

3.1)

 Segment and time of 

V

IBRO

 M

OTION

 

of the platform (turning angle 0 - 5º for a 
time period 1 - 5 sec) run on the borders
of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

3.2) 

P

AUSE

 duration for temporary platform 

motion 

stops

 (1 - 5 sec) when the vibro 

motion is off (the turning angle of vibro 
motion is set to zero)

 run on the borders

of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

Page 

4

·

Do not operate the unit if it is faulty or has been installed incorrectly.

·

Do not use outside laboratory rooms. 

·

Do not place a load exceeding the maximum load value mentioned in the 

Specifications section of this Manual.

BIOLOGICAL SAFETY

·

It is the user's responsibility to carry out appropriate decontamination if 
hazardous material is spilt on or 

penetrates into 

the equipment.

2

. General Information

Multi  Bio  RS-24 

p

rogrammable  rotator

 

provides:  1)  orbital  rotational 

motion, 2) reciprocal motion, 3) vibro motion of the platform in different planes 
according to the microprocessor protocol. The protocol 

enables making not 

only  programs  that  include  mixing  motion  of  one  particular  type,  but  also 
programs that alternate mixing motions of different types cyclically.

 

There are options for setting:

1) 

Speed and time of ordinary 

R

OTATIONAL

 M

OTION

 

(360º)

of the platform for a time period 0 - 250 sec, 

or non-stop

 with the speed of 1 - 100 rpm.

2) 

Segment of 

R

ECI

PRO

CAL

 M

OTION

 when

the direction of platform rotational

 motion

 

from 

the vertical plane is changing in turns within 
the limits of the set segment (turning angle 1 - 
90º for a time period 0 - 250 sec, or non-stop);

3.1)

 Segment and time of 

V

IBRO

 M

OTION

 

of the platform (turning angle 0 - 5º for a 
time period 1 - 5 sec) run on the borders
of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

3.2) 

P

AUSE

 duration for temporary platform 

motion 

stops

 (1 - 5 sec) when the vibro 

motion is off (the turning angle of vibro 
motion is set to zero)

 run on the borders

of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

·

Do not operate the unit if it is faulty or has been installed incorrectly.

·

Do not use outside laboratory rooms. 

·

Do not place a load exceeding the maximum load value mentioned in the 

Specifications section of this Manual.

BIOLOGICAL SAFETY

·

It is the user's responsibility to carry out appropriate decontamination if 
hazardous material is spilt on or 

penetrates into 

the equipment.

2

. General Information

Multi  Bio  RS-24 

p

rogrammable  rotator

 

provides:  1)  orbital  rotational 

motion, 2) reciprocal motion, 3) vibro motion of the platform in different planes 
according to the microprocessor protocol. The protocol 

enables making not 

only  programs  that  include  mixing  motion  of  one  particular  type,  but  also 
programs that alternate mixing motions of different types cyclically.

 

There are options for setting:

1) 

Speed and time of ordinary 

R

OTATIONAL

 M

OTION

 

(360º)

of the platform for a time period 0 - 250 sec, 

or non-stop

 with the speed of 1 - 100 rpm.

2) 

Segment of 

R

ECI

PRO

CAL

 M

OTION

 when

the direction of platform rotational

 motion

 

from 

the vertical plane is changing in turns within 
the limits of the set segment (turning angle 1 - 
90º for a time period 0 - 250 sec, or non-stop);

3.1)

 Segment and time of 

V

IBRO

 M

OTION

 

of the platform (turning angle 0 - 5º for a 
time period 1 - 5 sec) run on the borders
of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

3.2) 

P

AUSE

 duration for temporary platform 

motion 

stops

 (1 - 5 sec) when the vibro 

motion is off (the turning angle of vibro 
motion is set to zero)

 run on the borders

of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

·

Do not operate the unit if it is faulty or has been installed incorrectly.

·

Do not use outside laboratory rooms. 

·

Do not place a load exceeding the maximum load value mentioned in the 

Specifications section of this Manual.

BIOLOGICAL SAFETY

·

It is the user's responsibility to carry out appropriate decontamination if 
hazardous material is spilt on or 

penetrates into 

the equipment.

2

. General Information

Multi  Bio  RS-24 

p

rogrammable  rotator

 

provides:  1)  orbital  rotational 

motion, 2) reciprocal motion, 3) vibro motion of the platform in different planes 
according to the microprocessor protocol. The protocol 

enables making not 

only  programs  that  include  mixing  motion  of  one  particular  type,  but  also 
programs that alternate mixing motions of different types cyclically.

 

There are options for setting:

1) 

Speed and time of ordinary 

R

OTATIONAL

 M

OTION

 

(360º)

of the platform for a time period 0 - 250 sec, 

or non-stop

 with the speed of 1 - 100 rpm.

2) 

Segment of 

R

ECI

PRO

CAL

 M

OTION

 when

the direction of platform rotational

 motion

 

from 

the vertical plane is changing in turns within 
the limits of the set segment (turning angle 1 - 
90º for a time period 0 - 250 sec, or non-stop);

3.1)

 Segment and time of 

V

IBRO

 M

OTION

 

of the platform (turning angle 0 - 5º for a 
time period 1 - 5 sec) run on the borders
of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

3.2) 

P

AUSE

 duration for temporary platform 

motion 

stops

 (1 - 5 sec) when the vibro 

motion is off (the turning angle of vibro 
motion is set to zero)

 run on the borders

of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

·

Do not operate the unit if it is faulty or has been installed incorrectly.

·

Do not use outside laboratory rooms. 

·

Do not place a load exceeding the maximum load value mentioned in the 

Specifications section of this Manual.

BIOLOGICAL SAFETY

·

It is the user's responsibility to carry out appropriate decontamination if 
hazardous material is spilt on or 

penetrates into 

the equipment.

2

. General Information

Multi  Bio  RS-24 

p

rogrammable  rotator

 

provides:  1)  orbital  rotational 

motion, 2) reciprocal motion, 3) vibro motion of the platform in different planes 
according to the microprocessor protocol. The protocol 

enables making not 

only  programs  that  include  mixing  motion  of  one  particular  type,  but  also 
programs that alternate mixing motions of different types cyclically.

 

There are options for setting:

1) 

Speed and time of ordinary 

R

OTATIONAL

 M

OTION

 

(360º)

of the platform for a time period 0 - 250 sec, 

or non-stop

 with the speed of 1 - 100 rpm.

2) 

Segment of 

R

ECI

PRO

CAL

 M

OTION

 when

the direction of platform rotational

 motion

 

from 

the vertical plane is changing in turns within 
the limits of the set segment (turning angle 1 - 
90º for a time period 0 - 250 sec, or non-stop);

3.1)

 Segment and time of 

V

IBRO

 M

OTION

 

of the platform (turning angle 0 - 5º for a 
time period 1 - 5 sec) run on the borders
of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

3.2) 

P

AUSE

 duration for temporary platform 

motion 

stops

 (1 - 5 sec) when the vibro 

motion is off (the turning angle of vibro 
motion is set to zero)

 run on the borders

of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

·

Do not operate the unit if it is faulty or has been installed incorrectly.

·

Do not use outside laboratory rooms. 

·

Do not place a load exceeding the maximum load value mentioned in the 

Specifications section of this Manual.

BIOLOGICAL SAFETY

·

It is the user's responsibility to carry out appropriate decontamination if 
hazardous material is spilt on or 

penetrates into 

the equipment.

2

. General Information

Multi  Bio  RS-24 

p

rogrammable  rotator

 

provides:  1)  orbital  rotational 

motion, 2) reciprocal motion, 3) vibro motion of the platform in different planes 
according to the microprocessor protocol. The protocol 

enables making not 

only  programs  that  include  mixing  motion  of  one  particular  type,  but  also 
programs that alternate mixing motions of different types cyclically.

 

There are options for setting:

1) 

Speed and time of ordinary 

R

OTATIONAL

 M

OTION

 

(360º)

of the platform for a time period 0 - 250 sec, 

or non-stop

 with the speed of 1 - 100 rpm.

2) 

Segment of 

R

ECI

PRO

CAL

 M

OTION

 when

the direction of platform rotational

 motion

 

from 

the vertical plane is changing in turns within 
the limits of the set segment (turning angle 1 - 
90º for a time period 0 - 250 sec, or non-stop);

3.1)

 Segment and time of 

V

IBRO

 M

OTION

 

of the platform (turning angle 0 - 5º for a 
time period 1 - 5 sec) run on the borders
of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

3.2) 

P

AUSE

 duration for temporary platform 

motion 

stops

 (1 - 5 sec) when the vibro 

motion is off (the turning angle of vibro 
motion is set to zero)

 run on the borders

of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

·

Do not operate the unit if it is faulty or has been installed incorrectly.

·

Do not use outside laboratory rooms. 

·

Do not place a load exceeding the maximum load value mentioned in the 

Specifications section of this Manual.

BIOLOGICAL SAFETY

·

It is the user's responsibility to carry out appropriate decontamination if 
hazardous material is spilt on or 

penetrates into 

the equipment.

2

. General Information

Multi  Bio  RS-24 

p

rogrammable  rotator

 

provides:  1)  orbital  rotational 

motion, 2) reciprocal motion, 3) vibro motion of the platform in different planes 
according to the microprocessor protocol. The protocol 

enables making not 

only  programs  that  include  mixing  motion  of  one  particular  type,  but  also 
programs that alternate mixing motions of different types cyclically.

 

There are options for setting:

1) 

Speed and time of ordinary 

R

OTATIONAL

 M

OTION

 

(360º)

of the platform for a time period 0 - 250 sec, 

or non-stop

 with the speed of 1 - 100 rpm.

2) 

Segment of 

R

ECI

PRO

CAL

 M

OTION

 when

the direction of platform rotational

 motion

 

from 

the vertical plane is changing in turns within 
the limits of the set segment (turning angle 1 - 
90º for a time period 0 - 250 sec, or non-stop);

3.1)

 Segment and time of 

V

IBRO

 M

OTION

 

of the platform (turning angle 0 - 5º for a 
time period 1 - 5 sec) run on the borders
of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

3.2) 

P

AUSE

 duration for temporary platform 

motion 

stops

 (1 - 5 sec) when the vibro 

motion is off (the turning angle of vibro 
motion is set to zero)

 run on the borders

of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

·

Do not operate the unit if it is faulty or has been installed incorrectly.

·

Do not use outside laboratory rooms. 

·

Do not place a load exceeding the maximum load value mentioned in the 

Specifications section of this Manual.

BIOLOGICAL SAFETY

·

It is the user's responsibility to carry out appropriate decontamination if 
hazardous material is spilt on or 

penetrates into 

the equipment.

2

. General Information

Multi  Bio  RS-24 

p

rogrammable  rotator

 

provides:  1)  orbital  rotational 

motion, 2) reciprocal motion, 3) vibro motion of the platform in different planes 
according to the microprocessor protocol. The protocol 

enables making not 

only  programs  that  include  mixing  motion  of  one  particular  type,  but  also 
programs that alternate mixing motions of different types cyclically.

 

There are options for setting:

1) 

Speed and time of ordinary 

R

OTATIONAL

 M

OTION

 

(360º)

of the platform for a time period 0 - 250 sec, 

or non-stop

 with the speed of 1 - 100 rpm.

2) 

Segment of 

R

ECI

PRO

CAL

 M

OTION

 when

the direction of platform rotational

 motion

 

from 

the vertical plane is changing in turns within 
the limits of the set segment (turning angle 1 - 
90º for a time period 0 - 250 sec, or non-stop);

3.1)

 Segment and time of 

V

IBRO

 M

OTION

 

of the platform (turning angle 0 - 5º for a 
time period 1 - 5 sec) run on the borders
of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

3.2) 

P

AUSE

 duration for temporary platform 

motion 

stops

 (1 - 5 sec) when the vibro 

motion is off (the turning angle of vibro 
motion is set to zero)

 run on the borders

of reciprocal motion segment. It is available 
only when the reciprocal motion is ON;

Содержание Bio RS-24

Страница 1: ...Multi Bio RS 24 Programmable rotator for version V 3AW Operating Manual Certificate Medical Biological Research Technologies...

Страница 2: ...Contents 1 Safety precautions 2 General information 3 Getting started 4 Operation 5 Program setting 6 Specifications 7 Maintenance 8 Warranty and Claims 9 Declaration of Conformity Page 2...

Страница 3: ...ing and decontamination methods recommended by the manufacturer Do not make modifications to the design of the unit ELECTRICAL SAFETY Connect only to a power supply with voltage corresponding to that...

Страница 4: ...o run on the borders of reciprocal motion segment It is available only when the reciprocal motion is ON Do not operate the unit if it is faulty or has been installed incorrectly Do not use outside lab...

Страница 5: ...vide increased methodical means to researchers working in the field of modern molecular and cell biology and the developing biodiagnostics technology based on the use of magnetic particles for which u...

Страница 6: ...1 copy Optional accessories PRS 5 12 platform v on request PRS 10 platform w on request PRSC 22 platform x on request PRSC 10 platform y on request PRS 1DP platform z on request 3 3 Set up place the...

Страница 7: ...set and the timer indicator Fig 1 2 shows 0 00 pressing the Run Stop key will cause continuous operation of the rotator until the Run Stop key is pressed again 4 7 If the operation time is set the pla...

Страница 8: ...perations the microprocessor saves the last parameter changes as the working program automatically 5 4 The countdown timer is used to control the operation time The timer can be set for the period fro...

Страница 9: ...time of Reciprocal motion is shorter or equal to the set time of Vibro pause mode the Reciprocal motion mode will be omitted Orbital Pause 5 5 5 Reciprocal Rotation Set the speed 1 100 rpm for Orbital...

Страница 10: ...r performs soft vibration Vibro motion However there is a mode for hard vibration To perform hard vibration set the turning angle of Reciprocal motion to 90 and the angle of Vibro type motion to 1 Har...

Страница 11: ...ation mode Tilt angle range 1 90 increment 1 Time setting range 0 250 sec 6 3 Vibro pause mode Tilt angle range 0 5 increment 1 Time setting range 0 5 sec 6 4 Digital time setting 1 min 24 hours or no...

Страница 12: ...continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice Up to 100 g for platform with rubber clamps or 200 g for platf...

Страница 13: ...your local Biosan representative 7 2 All maintenance and repair operations must be performed only by qualified and specially trained personnel 7 3 Standard ethanol 75 or other cleaning agents recomme...

Страница 14: ...istributor to check availability of extended warranty 8 3 If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the loca...

Страница 15: ...Version 3 03 October 2012 9 Declaration of Conformity...

Страница 16: ......

Отзывы: