DVT10B3
-
12
-
After a new configuration completed, hold down the Mode button at next power on at the same time for
system initialization. (Notice: this will initialize controller based on configured parameters. This action will
force failed drive or rebuilding status to become
“Normal”. Please DO NOT do this if your system was in
degraded mode, and need to be recovered.) After power on, LCD should show its RAID mode and
“Normal” status.
RAID-6
NORMAL
2.4 RAID Operational Parameters
This section explains each RAID parameter and the associated function of DVPro system.
Ps. Please take a memo if you changed parameters different from its default value. You
can follow the method described on
「
Parameter Confirmation
」
section to read its
value.
Disk Size Setup
DISK Size
xxB
This is to specify the capacity of the drive you want to use. The size will be applied to all drives.
(Usually the system was configured with exact drive size of inserted disks. You should not change the drive
size unless you want to reconfigure and change it.
)
Parameter
Function
Memo
Test 1GB
Set DISK Size as 1GB (Test only)
120GB, 160GB, 250GB,
400GB, 500GB, 750GB,
1TB, 2TB, 3TB, 4TB
Set Disk Size as
● Please do not change the default setting
If actual drive size was smaller than setup value, error such as
「
ONE
DOWN L
」
,
「
SYSTEM DOWN L
」
might happen and buzzer will be fired.
RAID Mode Setup
RAID MODE
RAID-6
RAID mode selection, supported RAID MODE are
CAUTION
M
Содержание DVPro T10B3
Страница 2: ......
Страница 5: ...DVT10B3 2...
Страница 9: ...DVT10B3 6 Rear View Side View...
Страница 12: ...BIOS CORPORATION 9...
Страница 50: ...BIOS CORPORATION 47 2 8 3 IP Setup for MAC OS X Click System Preferences Click Network Icon...
Страница 52: ...BIOS CORPORATION 49...
Страница 58: ...BIOS CORPORATION 55 The New Volume Wizard will load up so click Next Choose the volume you want then click Next...