  System Overview

 

Qsep

™ 

Series are a fully-automated CE system developed by BiOptic Inc., which uses 

pen-shaped disposable gel-cartridges to improve efficiency. Time-consuming manual 

procedures  such  as  gel  preparation,  sample  loading,  and  capillary  changing  are  no 

longer  required.  Further,  the  information  will  be  obtained  easily  with  the  fully- 
automated 

Qsep

™ 

Series.

 

Qsep

400

™ is

 designed to accommodate the standard 96-well 

and 12 well PCR plate, respectively. 

 

Qsep

™ 

Series

’s

  compact  design  helps  you  to  set  up  and  operate  the  instrument 

intuitively.  The  disposable  gel-cartridge  with  integrated  pre-programmed  test 

methods makes capillary electrophoresis experiments no longer a painful procedure 

that  requires well-trained  operators. No more  worries  about  operation  and human 

errors caused by different operators which affect the accuracy and reproducibility of 

the results. 

 

The  following  sections  will  describe  the  product  overview,  the  functions  of

 

Qsep

™ 

Series  instruments  and  the  gel-cartridge.  Please  read  through  this  section  and  get 
ready to be amazed with the power of 

Qsep

™ 

Series.

 

 

Caution: 

The  operator  of  this  instrument  is  advised  that  if  the  equipment  is 

operated  in  a  manner  not  specified  in  this  manual,  the  protection  provided  by  the 

equipment may be impaired. 

 

 

Содержание Qsep 400

Страница 1: ...BiOptic Inc 4F No 108 3 Minquan Rd Xindian Dist New Taipei City 23141 Taiwan R O C www bioptic com tw Revolution Qsep400 Operation Manual Hardware...

Страница 2: ...s 4 Packing List 4 Cautions 6 1 Qsep400 Instrument 9 1 1 Qsep400 Front View 9 1 2 Qsep400 Back View 11 1 3 Qsep400 Top View 12 2 Installation Instruction 13 2 1 Environment Requirements 13 2 2 Power C...

Страница 3: ...is prohibited without prior written permission of BiOptic Inc except as allowed under the copyright laws Qsep Series and Q Analyzer are registered trademarks of BiOptic Inc Microsoft Windows is regist...

Страница 4: ...INSTRUCTIONS BiOptic Inc assumes no liability whatsoever for any personal injury property damage or other loss resulting from not complying or familiar with the manuals or improper operation of the d...

Страница 5: ...allation Disc including Q Analyzer for Qsep400 and Qsep Series Operation Manual Note The Software key contains 8GB storage space Q Analyzer for Qsep400 and Qsep Series Operation Manual including Hardw...

Страница 6: ...ce it upside down 4 Store the cartridge in the calm shell container Cartridge needs to be stored in a proper environment as the instructions of cartridge unpacking guide to maintain its lifetime and q...

Страница 7: ...lease disconnect the power plug 15 Please clean the instrument with dry cloth For other maintenance please contact local distributor 16 Please use the MAINS power cord within adequate rating 17 The co...

Страница 8: ...ntuitively The disposable gel cartridge with integrated pre programmed test methods makes capillary electrophoresis experiments no longer a painful procedure that requires well trained operators No mo...

Страница 9: ...e high voltage source of the capillary electrophoresis is ON B Main Power switch The blue LED lights up when it is turned on C Operation room Open the onboard computer module A rotation platform inclu...

Страница 10: ...10 Figure 1 2 Rotation platform...

Страница 11: ...iew A Air pressure gauge Display the value of the pressure operating in Qsep400 B Air flow Inlet Port Connect to an external pump using an 1 8 inches tube C USB Port Connect to a computer D Power Conn...

Страница 12: ...12 1 3 Qsep400 Top View Figure 1 4 Qsep400 top view A Cartridge door...

Страница 13: ...installation it is recommended to leave approximately 711 mm 28 inches clear space above the counter space or table Allow approximately 76 mm 3 inches of clear space at the rear and to the side of the...

Страница 14: ...in the package 100 240V AC 47 63Hz The dimensions are 12 2cm L 5 2cm W 3 5cm H and weight of the instrument is 26Kg Direct control the instrument with onboard computer Connect the air source within th...

Страница 15: ...ace Qsep400 instrument on a stable platform and ensure it is away from water and any other high power electronic devices Qsep400 needs to be operated in a clean and well ventilated environment Remove...

Страница 16: ...Qsep400 The message box of Purge function check will pop up after connected Follow the instruction and proceed the check before using is recommended User needs to perform the purge function check ever...

Страница 17: ...y into the tray holder Step 6 Alignment Marker AM Preparation Add at least 20 l Alignment Marker into the 0 2 ml tube 4 tubes and add 10 l Mineral Oil on the top of Alignment Marker Spin down and make...

Страница 18: ...l tube that placed at A1 A12 position must be removed cutoff Step 10 Click Park to move the holder back to the park position and click Close Sample Door Step 11 After unpacking cartridge open the cart...

Страница 19: ...se proceed with the following steps The storage and transportation condition may influence the cartridge and cause unstable current If current gray line is unstable during HV check please repeat this...

Страница 20: ...lumn and designate the sample locations test method and result name following steps 14 1 to 14 4 Step 14 1 Sample Position Mark the position of sample on the plate and then click OK Step 14 2 Method S...

Страница 21: ...Para Set the parameters Baseline Factor Peak Threshold Calculate Calculate Reference marker table based on built in size marker data Create size marker Place size marker at SM row on the holder create...

Страница 22: ...the results During Calibration Check the alignment markers have been placed in the correct position Software will recognize two peaks from Alignment Marker signal DO NOT use Size Marker or DNA sample...