16 

- loss of the delivery set contents mentioned in Item 1. INTRODUCTION; 
- willful damage;  
- repair (or attempt to repair) performed by an unauthorized individual;  
- power outages;  
- use of low quality fuel;  
-  for the  product that  was  installed and  adjusted by  a  company  or individual  that  are 

non-authorized by the manufacturing plant;  

- natural disasters (lightning strike, fire, flood, submergence, etc.). 

7. In case of revealing defects mentioned in item 6, repair is carried out at buyer’s 
    expense, and a buyer will be notified thereof prior to start of repair. 
8.  When  submitting  the  damage  certificate  it  is  required  to  add  the  description  of  a  defect, 
accurate return address and contact phone; otherwise the damage certificate will be reviewed 
within the longer time period. 
 
 
 

9 TRANSPORTATION 

 

For  the  purpose  of  keeping  (maintaining)  the  Controller  integrity  and  proper 

functionality during transportation one shall follow all the transportation conditions: 

- temperature and humidity (see Item 3 of this Manual); 
- stockpiling – not more than 10 ea.; 
- rain protection; 
- direct sun rays protection; 
- crush protection; 
- electromagnetic shielding. 
 

8 UNIT DISPOSAL 

 

It  is  prohibited  to  dispose  the  used  unit  in  containers  with  domestic  waste,  the 

Controller  shall  be  sent  to  the  special  enterprise.    Transfer  of  Controller  decomposition 
products to the environment might result in negative consequences. 

 

9 REGULATORY HISTORY 

 

All products of LTD «Bioprom Company Kharkov» undergo the certification process 

(certificate validation) on a yearly basis as well as periodic test for interference immunity in 
the  State  Enterprise  «KharkovStandardMetrology».  Certificates  can  be  found  on  the 
company sites. 
 

Содержание AIR BIO

Страница 1: ...1 OPERATION MANUAL FOR AIR BIO ELECTRONIC CONTROL UNIT FOR SOLID FUEL BOILER Kharkov city...

Страница 2: ...and fuel supply system AIR BIO delivery set includes 1 Network cable with plug tip 2 m long 1 ea 2 Wire for hooking up the fan with connector 0 5m long 1 ea 3 Wire for hooking up the pump 2m long 2 ea...

Страница 3: ...3 Picture1 AIR BIO Hookup Diagram Picture 2 AIR BIO Hookup to Central Heating System Diagram...

Страница 4: ...following advantages fuel significant saving because there is a capability to control burning intensiveness capability to adjust Hot Water Supply temperature capability to adjust Central Heating temp...

Страница 5: ...nector in intended to protect the unit from short circuit Control unit screen displays the boiler operation mode When entering the MENU it displays the menu items and modes for setting up the respecti...

Страница 6: ...tion time and interval time for fuel supply gear If boiler temperature is equal or higher than the preset temperature the Controller is in Standby mode Each Controller shall be adjusted individually d...

Страница 7: ...in Display When supplying power and pressing Power button the Controller LCD display will show the main page User Menu with the following information STANDBY t CH XX YY t HW XY YX ZZ screw t QQ Pictur...

Страница 8: ...ching off the pump check up of its operability 3 3 2 Firing ON OFF This function is intended for starting up the cold boiler When activating this function you transfer the boiler from Standby mode to...

Страница 9: ...when the boiler is in the mode of gaining temperature up to the preset value Delivery time Value is set up from 1 to 250 sec Delivery time is selected in accordance with boiler capacity fuel type and...

Страница 10: ...changes within the range of 30 95 b Pump Hysteresis changes within the range 1 10 3 3 7 Adjuster Menu This function allows adjusting basic parameters of the Controller s program 3 3 7 1 Screw feeder a...

Страница 11: ...em 3 3 9 Boiler Hysteresis Range 1 10 You set up the value up to which heat carrier operation temperature goes down from the preset temperature whereby the Controller will transfer the boiler from Sup...

Страница 12: ...temperature 45 9 Boiler hysteresis 5 5 PERFORMANCE DATA Parameter Description UoM Value 1 Power supply voltage V z 230 50 2 Max power input Watt 4 5 3 Automatic equipment operation temperature range 1...

Страница 13: ...troller central heating systems shall be equipped with safety valves operating under pressure surge tanks protective systems to ensure there will be no water boiling in the central heating system it i...

Страница 14: ...fire safety regulations and electrical safety requirements 2 Installation and adjustment of the Controller shall be carried out in the presence of the qualified specialist 3 It is recommended to insta...

Страница 15: ...is not less than 10 years 2 LTD Bioprom Company Kharkov provides warranty for AIR BIO Controller for the period of 18 months from the date of sale but not longer than 24 months from the date of manuf...

Страница 16: ...within the longer time period 9 TRANSPORTATION For the purpose of keeping maintaining the Controller integrity and proper functionality during transportation one shall follow all the transportation c...

Страница 17: ...a www bioprom kh ua www bioprom ua www bioprom kharkov ua For all issues relating to warranty and post warranty service please feel free to contact us at the address of 126 1 Plekhanovskaya Str Kharko...

Страница 18: ...18 For Notes...

Страница 19: ...19 For Notes...

Страница 20: ...oller is used in strict compliance with the manufacturer s specification Unit is checked by ______ Full Name ___________ signature Serial Number ______________________ Date Manufacturer s Signature an...

Отзывы: