6 APPLICATION INSTRUCTIONS FOR AIR BIO
6.1 Operating Restrictions
AIR BIO Controller for solid fuel boilers has the following operating restrictions:
Parameter Description
AIR BIO
Permissible humidity, %
from 40 to 90, non-
condensing
Permissible atmospheric pressure, kPa
from 84 to 107
Case proofness per GOST
14254
IP 41
Temperature sensor hardness, оС
from -55 to +125
6.2 Installation Rules
While installation and operation it is recommended to adhere to the following rules:
-
the Controller shall be used for its intended purpose only.
-
installation and removal of the Controller shall be carried out by the specialist
having the corresponding qualification;
-
all installation works associated with installation/removal of the unit or electric
wiring shall be carried out only after power cut (disconnect plug 220V from the main);
-
mistaken connection of electric wiring might result in damage of the Controller;
-
central heating systems shall be equipped with safety valves, operating under
pressure, surge tanks, protective systems to ensure there will be no water boiling in the
central heating system.
-
it is recommended to use the surge arrester for stable and accurate Controller
operation;
-
it is prohibited to make any changes in electrical and mechanical knots of the unit.
Such changes might result in improper Controller operation or its breakdown;
-
when hooking up the Controller make sure it will not cause overload in electric
network; avoid to hook up the unit to the same electric circuit along with engines and other
devices causing impulse interferences (e.g. washing machines, refrigerators, etc.);
-
it is prohibited to allow the unit to undergo strikes or vibration;
-
all connections shall be carried out in accordance with the electric installation
diagram and local norms on electric installations;
-
it is prohibited to use the controller with damaged cables (wires); the damaged cable
shall be replaced by a special service company, the cable shall be new with the same
parameters as the original one.