installation,  operation  and  repair  of  the  Controller  shall  be  carried  out  in  strict 

compliance with all the rules described in the Operation Manual; 

-

 

hookup, adjustment and technical maintenance of the Controller shall be carried out 

by  the  qualified  personnel  that  are  familiar  with  the  Controller  configuration,  hookup 
diagram,  НПАОП  40.1-1.21  and  «Regulations  for  Operation  of  Consumer  Electrical 
Installations» (ПТЭ); 

-

 

it is required to check the technical condition of wiring prior to start of the heating 

season and  inspect it from time to time; it is also required to check stability of position of 
the Controller during its operation;  

-

 

it is required to measure grounding effectiveness for the pump and fan. 

 

7.3 Storage Instructions

 

The Controller shall be stored in closed heated premises in cardboard boxes under the 

following conditions: 

-

 

surrounding air temperature from 0 to 40°С. 

-

 

relative air humidity of not more than 90% under temperature of 35°С. 

-

 

There should be no dust, fumes of acid and alkaline as well as aggressive gases in 

the premises air. 
 

8 WARRANTY OBLIGATIONS 

 

1. The life cycle for 

AIR BIO 

Controller determined by LTD «Bioprom Company Kharkov» 

is not less than 10 years. 
2.  LTD  «Bioprom  Company  Kharkov»  provides  warranty  for 

AIR  BIO 

Controller

 

for  the 

period  of

 

18  months  from  the  date  of  sale  but  not  longer  than  24  months  from  the  date  of 

manufacture. 
3.  Warranty  repair  can  be  performed  only  by  the  company-manufacturer  or  it  authorized 
service centers. 
4.  Warranty  repair  is  carried  out  within  3  working  days  from  the  date  of  receiving  the 
Controller by the service center, in certain cases the repair period can be prolonged up to 14 
days. 
5. 

Warranty is valid:  

- only on the territory of the country where the Controller was purchased;  
- 12  months  on  conditions  that  the  Controller  and  the  boiler  have  been  operated 

properly in strict compliance with manuals for the Controller and the boiler; 

- if the user has not incorporated (made) any changes into the Controller configuration 

and construction;  

 

- if the works on putting the Controller into operation have been carried out by the 

authorized representative of the manufacturing plant. The list of authorized representatives of 
the  manufacturing  plant  can  be  found  on  website  of  LTD  «Bioprom  Company  Kharkov» 
bioprom.ua.   
6. Warranty 

does not cover

 damages occurred through:  

user’s fault due to improper installation of the unit and/or boiler;  

-  user’s  fault  due  to  violation  of  operation  rules  described  in  the  present  Manual  or 

Boiler Operation Manual;  

Содержание AIR BIO

Страница 1: ...1 OPERATION MANUAL FOR AIR BIO ELECTRONIC CONTROL UNIT FOR SOLID FUEL BOILER Kharkov city...

Страница 2: ...and fuel supply system AIR BIO delivery set includes 1 Network cable with plug tip 2 m long 1 ea 2 Wire for hooking up the fan with connector 0 5m long 1 ea 3 Wire for hooking up the pump 2m long 2 ea...

Страница 3: ...3 Picture1 AIR BIO Hookup Diagram Picture 2 AIR BIO Hookup to Central Heating System Diagram...

Страница 4: ...following advantages fuel significant saving because there is a capability to control burning intensiveness capability to adjust Hot Water Supply temperature capability to adjust Central Heating temp...

Страница 5: ...nector in intended to protect the unit from short circuit Control unit screen displays the boiler operation mode When entering the MENU it displays the menu items and modes for setting up the respecti...

Страница 6: ...tion time and interval time for fuel supply gear If boiler temperature is equal or higher than the preset temperature the Controller is in Standby mode Each Controller shall be adjusted individually d...

Страница 7: ...in Display When supplying power and pressing Power button the Controller LCD display will show the main page User Menu with the following information STANDBY t CH XX YY t HW XY YX ZZ screw t QQ Pictur...

Страница 8: ...ching off the pump check up of its operability 3 3 2 Firing ON OFF This function is intended for starting up the cold boiler When activating this function you transfer the boiler from Standby mode to...

Страница 9: ...when the boiler is in the mode of gaining temperature up to the preset value Delivery time Value is set up from 1 to 250 sec Delivery time is selected in accordance with boiler capacity fuel type and...

Страница 10: ...changes within the range of 30 95 b Pump Hysteresis changes within the range 1 10 3 3 7 Adjuster Menu This function allows adjusting basic parameters of the Controller s program 3 3 7 1 Screw feeder a...

Страница 11: ...em 3 3 9 Boiler Hysteresis Range 1 10 You set up the value up to which heat carrier operation temperature goes down from the preset temperature whereby the Controller will transfer the boiler from Sup...

Страница 12: ...temperature 45 9 Boiler hysteresis 5 5 PERFORMANCE DATA Parameter Description UoM Value 1 Power supply voltage V z 230 50 2 Max power input Watt 4 5 3 Automatic equipment operation temperature range 1...

Страница 13: ...troller central heating systems shall be equipped with safety valves operating under pressure surge tanks protective systems to ensure there will be no water boiling in the central heating system it i...

Страница 14: ...fire safety regulations and electrical safety requirements 2 Installation and adjustment of the Controller shall be carried out in the presence of the qualified specialist 3 It is recommended to insta...

Страница 15: ...is not less than 10 years 2 LTD Bioprom Company Kharkov provides warranty for AIR BIO Controller for the period of 18 months from the date of sale but not longer than 24 months from the date of manuf...

Страница 16: ...within the longer time period 9 TRANSPORTATION For the purpose of keeping maintaining the Controller integrity and proper functionality during transportation one shall follow all the transportation c...

Страница 17: ...a www bioprom kh ua www bioprom ua www bioprom kharkov ua For all issues relating to warranty and post warranty service please feel free to contact us at the address of 126 1 Plekhanovskaya Str Kharko...

Страница 18: ...18 For Notes...

Страница 19: ...19 For Notes...

Страница 20: ...oller is used in strict compliance with the manufacturer s specification Unit is checked by ______ Full Name ___________ signature Serial Number ______________________ Date Manufacturer s Signature an...

Отзывы: