The IS1001 reader can be operated and configured locally using the USB communication port.
Note:
BioTerm or BioStat and the proper driver must be installed on your computer. If your
computer is missing these programs, see the
Pre-Installation Steps
section on page 8.
1. Connect the IS1001 reader to a local computer using a USB type A-to-mini USB type B cable
(not supplied).
2. Start the BioTerm or BioStat communication program.
3. In the
Serial Port
box, make sure that
COMx Silicon Labs CP210x USB to UART Bridge
is
selected (where x is the port n
umber assigned to the local computer’s USB port).
4. In the
Baud Rate
box, make sure you match the IS1001 reader
’s Local Port speed setting.
5. Make a serial port connection to the IS1001 reader by clicking on the
Open
button.
6. To verify the connection between the computer and the IS1001 reader, within BioTerm or
BioStat
Traffic
window type
?
and then press
Enter
. A list of available commands should be
displayed. All the commands are described in detail on page 28.
7. Type appropriate commands to perform the desired actions.
8. To save all communication data, such as tag IDs, alarm messages, reports, etc., in a text file
configure the BioTerm utility program to act as a data logger by selecting
Tools > Enable
Capture
or by clicking on the
Text Capture On/Off
button.