biolog id SMART STORAGE AGITATOR 30 Скачать руководство пользователя страница 26

 

User Manual Smart Storage Agitator 30

 

Version

 : 1.0 

 

Validation date of the manual: 01/08/2021 

26 of 29 

 

6

 

First Level Maintenance 

This chapter describes the first-level failures, which you can meet when using the SST-A30. 

LED Light Status 

 

Actions to be taken 

The calculator has the 

ORANGE 

LED OFF 
 

The battery is not charging and 
potentially discharged. 

 

1. Make sure the calculator is 
correctly powered. 
2. Contact Biolog-id support. 

The calculator has the 

GREEN 

LED OFF & RED LED ON steady 
 

Hardware failure or network 
disconnection. 

 

1. Check connection to ethernet 
cable and/or reset network switch 
device. 
2. Change for maintenance mode 
and then restart the calculator. 
3. Contact Biolog-id support. 

The calculator has the 

GREEN & 

RED LED ON steady 
 

Software crashed. 

 

1. Change for maintenance mode 
and then restart the calculator. 
2. Contact Biolog-id support 

The drawer satellite has 

ORANGE LED ON steady 
 

An error occurs while 
reading/writing an RFID chip 
with no hardware failure 
identified. 

 

Moving the bags to another location 
and try again.

 

The satellite has 

RED LED ON 

steady 
 

Hardware failure.

 

 

Note: There is potentially no 
traceability at the location 
where the indicator is red.

 

 

1. Move the bags to a functional 
drawer. 
2. Satellite has become loose. Push 
satellite back into place. 
3. Change for maintenance mode 
and then restart the calculator. 
4. Contact Biolog-id support 

The satellite has the 

LED OFF 

 

Hardware OFF or failure. 

 

1. Move the bags to a functional 
drawer. 
2. Check that the satellite is well 
connected. 
3. Make sure the calculator is 
correctly powered. 
4. Change for maintenance mode 
and then restart the calculator. 
5. Contact Biolog-id support. 

 

In case of fault, the RFID traceability can be interrupted. This interruption is referenced in the 
product event log. 

Содержание SMART STORAGE AGITATOR 30

Страница 1: ...NUAL SMART STORAGE AGITATOR 30 SST A30 Headquarters 1 rue du Commandant Robert Malrait ZA des Granges BP 30303 27303 Bernay cedex France Phone 33 0 2 32 47 83 40 Fax 33 0 2 32 47 83 50 Web www biolog...

Страница 2: ...ower 8 2 3 2 Drawer 9 2 3 3 Satellite 9 2 3 4 Temperature sensor 10 2 3 5 Agitator sensor 10 2 4 Hardware and software compatibility 10 2 4 1 Agitator 10 2 4 2 Climate chamber 10 2 4 3 RFID tag 11 2 4...

Страница 3: ...tion date of the manual 01 08 2021 3 of 29 5 Cleaning Instructions 25 6 First Level Maintenance 26 7 Warranty 27 8 Transport 27 9 Manufacturer Responsibility 27 10 Lifetime 28 11 Disposal and recyclin...

Страница 4: ...ined for the life of your equipment 1 2 Manual Recipient This manual is for all users groups in SST A30 throughout its cycle of usage All topics and important areas for different groups are treated 1...

Страница 5: ...e SST A30 is a class I medical device used as an accessory to the Helmer PF48 Platelet Agitator The SST A30 is a Radio Frequency Identification RFID product applied to the traceability of Platelet Con...

Страница 6: ...ges the climatic aspects temperature and hygrometry of conservation of labile blood products SST A30 does not alter the performance of the platelet agitator nor the performance of the incubator in whi...

Страница 7: ...8 2021 7 of 29 3 months 20 C to 45 C 1 month 20 C to 60 C Button cell CR2032 Recommended 10 C to 25 C not to exceed 30 C Operating Humidity 40 RH to 95 RH Maximum storage humidity 40 RH to 95 RH FYI C...

Страница 8: ...components of the SST A30 as well as their function Fig 3 SST A30 set 2 3 1 Calculator and Power Fig 4 Calculator and its power supply set The calculator in the SST A30 system is responsible for manag...

Страница 9: ...29 2 3 2 Drawer The drawer is the component for storing the PC bags Fig 5 Drawer 2 3 3 Satellite A RFID satellite placed between two drawers allows the localization of PC bags The satellite is a subse...

Страница 10: ...s to measure the temperature of an area Fig 7 Temperature sensor Only the temperature of the climatic chamber incubator is the reference SST A30 has no claimed performance regarding temperature The SS...

Страница 11: ...ntered on the bag Fig 8 Platelet concentrate bag and RFID tag Fig 9 Tag positioning You must place your RFID tag on the center of your bag so that the RFID tag cannot be within 2cm of the edges of the...

Страница 12: ...a third party software and communicate via its web service to share exchange PC traceability data standard communication protocol The third party software can then request the SST A30 to write data to...

Страница 13: ...2 Place the PC bag on the drawer Note In diagnostic mode verification of the operation of RFID and LEDs the front of the satellite flashes PC bags can be placed in any direction in the width or length...

Страница 14: ...potentially discharged Refer to chapter First Level Maintenance of this manual GREEN LED ON steady RED LED OFF Normal and functional operation mode GREEN LED ON blinking RED LED OFF Maintenance and fu...

Страница 15: ...re details above this table ORANGE LED ON blinking A drawer is left open more than 4 minutes Close the drawer RED LED ON steady Note There is potentially no traceability at the location where the indi...

Страница 16: ...tellite 2 is lit in orange drawer 3 The LED of satellite 2 is lit in orange The LED of satellite 3 is lit in orange drawer 4 The LED of satellite 3 is lit in orange The LED of satellite 4 is lit in or...

Страница 17: ...ed in the Platelet agitator so that it cannot be disassembled without the use of a tool as part of a maintenance operation Never allow water or other liquids to enter the equipment to avoid the risk o...

Страница 18: ...stallation site on the nameplate before connecting the installation Electric Follow the wiring diagrams of the machine Electric Connect inevitably the device to a socket protected by a protective cond...

Страница 19: ...ility The SST A30 complies with applicable electromagnetic compatibility standards however the user will ensure that any electromagnetic interference does not create an additional hazard such as radio...

Страница 20: ...to be used in an electromagnetic environment in which radiated RF disturbances are controlled The user or installer of the medical device can help prevent any electromagnetic interference by maintaini...

Страница 21: ...power supply lines 2 kV for power supply lines 1 kV for signal ports Professional healthcare facility environment Surges IEC61000 4 5 1 kV in Differential mode 2 kV in common mode 1 kV in Differentia...

Страница 22: ...rsely affected Radiated RF electromagnetic fields IEC61000 4 3 3 V m 80 MHz to 2 7 GHz 80 MA at 1 kHz 3 V m 80 MHz to 2 7 GHz 80 MA at 1 kHz Professional healthcare facility environment Proximity fiel...

Страница 23: ...ouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment...

Страница 24: ...e collocated or operating in conjunction with any other antenna or transmitter Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploita...

Страница 25: ...t spray to the area to be treated or to a nonwoven wipe 2 Distribute the product To clean and maintain the proper functioning of the SST A30 we advise you to follow the instructions below Before each...

Страница 26: ...e mode and then restart the calculator 2 Contact Biolog id support The drawer satellite has ORANGE LED ON steady An error occurs while reading writing an RFID chip with no hardware failure identified...

Страница 27: ...third party system Contact the administrator Contact the supplier of your device in case of malfunction Do not repair or modify the device without prior authorization from Biolog Id Any maintenance o...

Страница 28: ...al regulations The individual components of the SST A30 must be sorted and processed according to the appropriate waste disposal channels The different components of the SST A30 being electrical and e...

Страница 29: ...d to each supplier and provided by BIOLOG_ID BI represents Biolog Id Year 2 characters 00 to 99 16 represents 2016 Week 2 characters 01 to 52 45 represents week 45 Serial number 6 characters 000001 to...

Отзывы: