background image

2

1. INTENDED 

USE

This liquid handling device is designed and manufactured to be used  with 

the IVD-product as an IVD-accessory  and as a stand alone laboratory 

equipment.

2.  YOUR NEW BIOHIT MIDI PLUS

The Biohit Midi Plus has been carefully designed and manufactured as a 

lightweight, cordless pipetting controller. It can be used with all plastic or 

glass pipets between 1-100 ml and also with Biohit 5 ml (Cat. No. 780300) 

and 10 ml (Cat. No. 780310) tips. The pipet adapters that allow the use with 

the Biohit  5 ml and 10 ml tips are available as accessories. The linear speed 

control allows the aspiration and dispensing speeds to be adjusted easily 

and precisely to suit either large- or small-volume pipets. The aspiration 

and dispensing speeds can also be 

fi

 ne-tuned during operation by applying 

varying 

fi

 nger pressure to the operating buttons.

 

The Midi Plus has been designed so that it can be suspended for the 

duration of pipetting. This option can be employed to reduce the strain 

associated with long operating periods. The Midi Plus also features an 

attached support which allows the unit to be rested on a table between 

dispensing routines with a pipet attached.

Cat. No.

Product

71093X

Biohit Midi Plus

X: 0 = Without AC-adaptor; 1 = With universal AC-adaptor (Euro, USA/Jpn, UK and 
China plugs)

3.  UNPACKING AND PREPARING THE MIDI  PLUS FOR USE

The Midi Plus package contains the following items:

•  Midi Plus pipetting controller

•  AC-adaptor

•  0.45 

μ

m hydrophobic 

fi

 lters

•  Instructions for use

•  Quality control certi

fi

 cate

Please check that all the items are included and nothing has been damaged 

during shipment.

Содержание Midi Plus

Страница 1: ...Midi Plus Instruction Manual Bedienungsanleitung Mode d emploi Manual Usaria Instruzioni d impiego Bruksanvisning K ytt ohje...

Страница 2: ...Instruction Manual 1 Bedienungsanleitung 13 Mode d emploi 25 Manual Usaria 37 Istruzioni d impiego 49 Bruksanvisning 61 K ytt ohje 73 Spare Parts See inside back cover BIOHIT Midi Plus...

Страница 3: ...ttons 5 5 2 Speed adjustment wheel 5 5 3 Pipet adapters 5 5 4 Filters 6 5 5 Support 6 6 OPERATING THE MIDI PLUS 6 6 1 Adjusting the operating speed 6 6 2 Inserting a pipet 6 6 3 Aspiration 7 6 4 Dispe...

Страница 4: ...ts The aspiration and dispensing speeds can also be fine tuned during operation by applying varying finger pressure to the operating buttons The Midi Plus has been designed so that it can be suspended...

Страница 5: ...transformer if it will be out of use for a lengthy period of time 3 2 Low battery indicator When the battery is close to empty the battery capacity indicator starts to blink Fig 2 The unit can still b...

Страница 6: ...SA PC Handle cover release buttons ASA PC Support PA Suspenison hook ASA PC 3 3 Electrical specifications Batteries AA 3 x 1 2 V 350 mAh NiCd Approx 7 hours service life when fully charged Charging ti...

Страница 7: ...ers The pipet adapter provided with the Midi Plus allows the use of all standard plastic and glass pipets graduated and non graduated including Pasteur pipets The pipet adapter of the Midi Plus consis...

Страница 8: ...mediately 5 5 Support The Midi Plus also features an attached support for placing the unit on the table between the dispensing routines with a pipet attached Fig 4 6 OPERATING THE MIDI PLUS 6 1 Adjust...

Страница 9: ...ut 2 Pressing the dispensing button further down engages the motor and activates the blow out function Note Finger pressure can be varied to fine tune the speed within each mode 6 5 Other pipetting re...

Страница 10: ...your Midi Plus 8 1 Decontamination To decontaminate lightly spray the outside of the Midi Plus with the Biohit Proline Biocontrol decontamination spray cat no 724004 5 l and wipe dry with a clean clo...

Страница 11: ...uid movement If overfilling occurs change the filter immediately Both sterile and non sterile filters are available Cat No Product Qty 712912 Filter for Biohit Midi Plus non sterile 5 pcs 712913 Filte...

Страница 12: ...VOID IF FAULT IS FOUND TO HAVE BEEN CAUSED BY MALTREATMENT MISUSE UNAUTHORIZED MAINTENANCE OF SERVICE OR NEGLIGENCE OF REGULAR MAINTENANCE AND SERVICE ACCIDENTAL DAMAGE INCORRECT STORAGE OR USE OF THE...

Страница 13: ...Directive 98 79 EC 11 RECYCLING INSTRUCTION WEEE In compliance with European Directive WEEE 2002 96EC on waste and reducting of hazardous substances in electical and electronic equipments this device...

Страница 14: ...12 Notes...

Страница 15: ...t 3 pcs 712991 Silicon adapter Standard 712893 10 ml 712911 5 ml 712910 Pump speed adjustment assembly 712111 Tubing set 712112 Pump assembly 712113 Connection valve 712114 Hydrophobic fi lter 0 45 m...

Страница 16: ...tions contenues dans cette publication sont jour au moment de la publication et ont t compil es avec le plus grand soin Biohit n est pas responsable des ventuelleserreursouomissionsetser serveledroitd...

Отзывы: