Gene Explorer Thermal Cyeler Operation Manual                                           

Chapter Four Operation Instructions 

 

12

 

 

 

Interface 1-1 

 

 

1-2 

Содержание BYQ6627E

Страница 1: ...Thermal Cycler GeneExplorer Series Operation Manual Hangzhou Bioer Technology Co Ltd...

Страница 2: ...m Hangzhou Bioer Technology Co Ltd any part of the document shall not be copied re produced or translated into other language Product patent No ZL 98 2 44367 6 Product technology requirement No Produc...

Страница 3: ...arising from user s failure for abiding by the following requirements Attention The instrument is Type I equipment in line with GB4793 1 standard with protection level of IP20 The instrument is design...

Страница 4: ...e place should be well ventilated and free from corrosive gas or high magnetic field interruption Don t place the instrument in moisty or dusty area Also don t place the instrument in area making it d...

Страница 5: ...vorable heat conduction If there is any dirt on the instrument surface use soft cloth dipped with cleansing cream to clean Warning The power must be cut off when cleaning the instrument surface Corros...

Страница 6: ...age or missing please immediately contact the supplier After acceptance inspection fill out the Acceptance Inspection Form and send the copy or fax back to the company for filing and warranty service...

Страница 7: ...n Instructions 8 1 Turn on the instrument 8 2 PCR program editing 10 2 1 Setting of program section 10 2 2 Section temperature and constant temperature time 11 2 3 Function of loop 11 2 4 Extended par...

Страница 8: ...lecular biology development 2 Examples of PCR s applications Application of thermal cyeler The product is applicable to polymerase chain reaction in fields including immunology human genome engineerin...

Страница 9: ...aking a leading position among similar products has combined various advanced technologies and can meet requirements of various PCR experiments Suitable consumables of GeneExplorer thermal cyeler are...

Страница 10: ...tion to reliable grounding of the power line 2 Transport and storage condition Ambient temperature 20 C 55 C RH 80 3 Basic parameters Product name GeneExplorer Product No BYQ6627E Model GE 48DS Featur...

Страница 11: ...imum number of loop is 99 available for secondary nesting gradient temperature range is 6 6 2 file storage 3 file modification including adjustment of ramp rate automatic temperature time modification...

Страница 12: ...ations before turning on the instrument If the instrument is used for the first time please be familiar with the contents in the chapter before turning on the machine 1 Structural schematic diagram Th...

Страница 13: ...ne is reliably grounded 3 Turn on the instrument Turn on the power switch switch to the position of and then the instrument will carry out self test which will take about 20s please wait patiently If...

Страница 14: ...supplier Attention If the sample volume of your experiment is less than the number of cone holes of the module please evenly distribute the test tubes to ensure stable press of the hot lid on the test...

Страница 15: ...yeler Operation Manual Chapter Four Operation Instructions 9 Press the icon New Experiment to enter into the interface of experiment parameter setting Press the icon Open Experiment to enter into the...

Страница 16: ...to enter into the interface of experiment parameter setting 2 PCR program editing Click New File on the main interface or click New Experiment under Open Experiment or Recently Opened to enter into th...

Страница 17: ...ram section Run mode Standard Mode and High speed Mode Standard Mode running characteristics simulate BIOER TOUCH series 2 3 Function of loop On the interface of PCR program setting click Loop and it...

Страница 18: ...Gene Explorer Thermal Cyeler Operation Manual Chapter Four Operation Instructions 12 Interface 1 1 1 2...

Страница 19: ...peed ramp rate Ladder Temp It refers to the temperature difference between two adjacent modules The range is 6 6 Temperature is set to the temperature of the leftmost module 2 5 Save experiment On the...

Страница 20: ...Gene Explorer Thermal Cyeler Operation Manual Chapter Four Operation Instructions 14 Click it will display the temperature of each module...

Страница 21: ...agent is inconsistent with our settings that the actual time of reagent reaching set temperature is shorter than the set time see the figure below for the relation between module temperature and reage...

Страница 22: ...opdown list on the upper left to select disk for operation For example select USB flash disk to operate on USB flash disk contents GeneExplorer Press New Experiment to enter into the interface of expe...

Страница 23: ...Gene Explorer Thermal Cyeler Operation Manual Chapter Four Operation Instructions 17 Press Function to delete or rename user Select user to export to USB flash disk Click Manage File...

Страница 24: ...nter the interface of setting which includes two major functions which are System Settings and Personal Center 5 1 Personal Center In Personal Center you can log on with registered account or log out...

Страница 25: ...Dairy 7 About instruments 8 Tm calculation 9 Buzzer setting 10 Exit exit system software 6 Software upgrade 6 1 UI program upgrade Copy file to USB flash disk version update Enter into System Settings...

Страница 26: ...rer Thermal Cyeler Operation Manual Chapter Four Operation Instructions 20 6 2 Driver upgrade File Copy to USB flash disk GeneExplorer location Enter into System Settings about instruments select driv...

Страница 27: ...damage or loose contact Hot lid sensor damage or loose contact 3 Evident change of module temperature rise rate or imprecise temperature control Blocked ventilation holes Remove the blocking objects o...

Страница 28: ...reaction tubes tightly and then put into the instrument Explanation for Err code 0x 0000 is as below 0X Left sensor Right sensor Reserved Reserved Reserved Reserved Single module hot lid double module...

Страница 29: ...Gene Explorer Thermal Cyeler Operation Manual Appendix 1 23 Appendix 1 Wiring Diagram the diagram is only for reference and please understand that no further notice will be given for any modification...

Страница 30: ...ction of the cycle X any existing section number to 00 Ending section of the cycle X 15 7 Grad Gradient temperature C 0 30 8 Date Date YY MM DD 00 99 01 12 01 31 YY MM DD 9 Time Time HH MM SS 00 00 00...

Страница 31: ...Gene Explorer Thermal Cyeler Operation Manual Appendix 2 25 15 Key Sound Key sound yes no Yes No Buzz 16 Run End Sound Run end sound yes no Yes No Intermittent buzz 2 1 Module Reagent Module Reagent...

Страница 32: ...ge 2kV 4kV 8kV Contact discharge 2kV 4kV B Radiation magnetic field GB T 17626 3 3V m 80MHz 2 0GHz 80 AM A Rated PFMF a GB T 17626 8 3A m 50Hz A AC Voltage sag d GB T 17626 11 1 cycle 0 B 5 cycle 40 C...

Страница 33: ...ducted on AC input port of AC DC power adapter specified by the manufacturer If there is no specific requirement typical AC DC power adapter should be adopted The test is applicable to DC power input...

Страница 34: ...Model Specification Unit QTY Remark 1 Power line with shield magnetic ring clamp 250V10A String 1 Accessory 2 Fuse 250V12A 5 20 Piece 2 Accessory 3 WiFi Module Piece 1 Accessory 4 Ethernet Patch Cable...

Страница 35: ...Add 1192 Bin An Rd Hi tech Binjiang District Hangzhou P C 310053 Tel 86 571 87774575 or 87774303 Fax 86 571 87772210 E mail overseas bioer com cn www bioer com cn Hangzhou Bioer Technology Co Ltd...