background image

3

Loop-Powered Process Meter

DPM-400

www.binmaster.com

Five (5) 0.7" Large 

Digits on Top Line  

in Feet & Inches

LED Backlight 

Feet & Inches  

Designation

Front Panel 

Buttons for Setup, 

Programming, and 

Operation

Bargraph for Visual 

Representation of 

Level Applications

NEMA 4X, IP65 Front

8-Digit Alphanumeric 

Bottom Line for Tag

or Dual Scale

Fractions of an Inch

Feet & Inches Level Meter with Bargraph

DISPLAY FEATURES

The DPM-400's display provides multiple ways to help users 

understand and keep track of their processes. The most obvious is 

the dual line which typically allows the user to display a numeric value 

of the process variable on the top line and units and/or a tag on the 

bottom line. There is also a bargraph that includes a numeric value of 

the percentage the bargraph represents. Finally, to alert users to an 

alarm condition, the display can turn red and flash an alarm message. 

Dual-Line Display with PV/Units/Tag/Bargraph

One of the most common configurations of these instruments is 

displaying the process variable on the top line and units and a tag 

toggling on the bottom line with a bargraph for additional clarity:

To help users get a quick understanding of where their process is at, 

certain DPM-400 models are available with a 20-segment bargraph. 

This bargraph also includes a numeric value of the percentage the 

bargraph represents. 

PV on the top line; units and tag toggling on the bottom line

Level in Feet & Inches with tag and bargraph

Alarms Indicated by Flashing Red Messages

When an alarm occurs, the DPM-400’s display can be programmed to 

turn red and flash an alarm message along with the process variable. 

The DPM-400’s flashing red alarm message can be activated even if 

no relay or open collector is connected.

Height Units on Top

Volume Units on Bottom 

Feet Value on Top

Gallons Value on Bottom 

Same Meter with Bottom Line toggling between 

tag, volume (62,346), and units (Gallons) 

Dual-Scale Display Feature

Users can use the DPM-400’s dual-scale feature when they want to 

show the same input in two different scales. For instance, the following 

example shows an application where the DPM-400 displays the input 

in feet and gallons:

Display Feet & Gallons and Toggle Between Units

Feet & Inches Display with Bargraph

There are DPM-400 models available for users that prefer to see 

their level displayed in feet & inches instead of decimal format. These 

versions can display level to 999FT 11IN & 15/16 on the top line. The 

bottom line can toggle between a tag and units or if dual scale mode is 

used, can display the input in a different scale such as volume.

Содержание DPM-400

Страница 1: ...Safe Area Operating Temperature Range Free PC Based USB Programming Software 5 Digit Alphanumeric Top Line 8 Digit Alphanumeric Bottom Line Displays Level in Feet Inches up to 999 Feet 11 15 16 Inche...

Страница 2: ...hese loop powered meters can be installed virtually anywhere because they get their power from the 4 20 mA loop and therefore require no separate power source And they only drop 1 5 V 4 7 V with backl...

Страница 3: ...process is at certain DPM 400 models are available with a 20 segment bargraph This bargraph also includes a numeric value of the percentage the bargraph represents PV on the top line units and tag tog...

Страница 4: ...and the relays are not available with pulse features The open collectors and relays can be controlled either automatically or manually The alarm status with flashing red message will show on the disp...

Страница 5: ...mmodate under and over ranges from 1 to 23 mA The output can be reverse scaled such that the meter s high calibration value outputs 4 mA and the meter s low calibration outputs 20 mA PUMP CONTROL DPM...

Страница 6: ...inputs for instance 0 0 and 2000 0 Round Horizontal Tank Linearization This function automatically calculates the volume in a round horizontal tank with flat ends Square Root Linearization The square...

Страница 7: ...ow a 4 20 mA loop connected to the meter The first figure shows the connection without the backlight and the second shows the connection with the backlight The meter is powered by the 4 20 mA current...

Страница 8: ...t Powered by 4 20 mA loop Intensity varies with signal level PD6603 BM Top line 99FT 11IN 15 16 to 999FT 11IN 15 16 Bottom line 8 digits 9 999 999 to 99 999 999 separated by commas or 8 characters all...

Страница 9: ...set after cleared manual reset only after alarm has cleared Alarm Indication Red backlight flashing display alarm symbol symbols not available on bargraph models Bargraph segment flashes on alarm Alar...

Страница 10: ...ed to The Relay Output window is used to assign a specific task to the 2 relays such as alarm sample timer stopwatch or off A custom message that will flash every 10 seconds can also be added The 4 20...

Страница 11: ...Powered General Purpose Feet Inches Two Solid State Relays PD6603 L3N BM Loop Powered General Purpose Feet Inches 4 20 mA Analog Output PD6603 L5N BM Loop Powered General Purpose Feet Inches Two Solid...

Отзывы: