Loop-Powered Process Meter

DPM-400

www.binmaster.com

Free, PC-based, MeterView XL software that connects to the meter 

via a micro USB cable is available for programming and setup of the 

meters. This software greatly simplifies the programming process and 

also allows the user to save configuration files for later use. The meter 

will also be powered by the USB connection so no additional power is 

needed during programming.

▲  

The main screen displays an image of the connected meter and 

includes various information about this meter, such as model 

number, readings, and status.

▲  

The Input/Scale window is used to: 

▲ 

 The Relay Output window is used to assign a specific task to the 2 

relays such as alarm, sample, timer, stopwatch, or off. A custom 

message that will flash every 10 seconds can also be added.

  The 4-20 mA Output window is used to program the isolated 

4-20 mA output’s source, range, and under and over range values.

FUNCTION

THIS METER

Set the input

4-20 mA

Enable/disable the totalizer

Totalizer enabled

Enable/disable the dual-scale feature

Dual scale disabled

Scale the input

Linear input, unit is gallons,  

2 cal points,  4-20 mA = 0-100 GAL

 Free PC-Based USB Programming Software

 Easy Programming of Features Packed Product

 USB Connection Provides Power During Programming

 Save & Print Configuration Files without Meter Connected

 Micro USB Cable Provided

FREE SIMPLE-TO-USE METERVIEw XL PROGRAMMING SOFTwARE

Содержание DPM-400

Страница 1: ...Safe Area Operating Temperature Range Free PC Based USB Programming Software 5 Digit Alphanumeric Top Line 8 Digit Alphanumeric Bottom Line Displays Level in Feet Inches up to 999 Feet 11 15 16 Inche...

Страница 2: ...hese loop powered meters can be installed virtually anywhere because they get their power from the 4 20 mA loop and therefore require no separate power source And they only drop 1 5 V 4 7 V with backl...

Страница 3: ...process is at certain DPM 400 models are available with a 20 segment bargraph This bargraph also includes a numeric value of the percentage the bargraph represents PV on the top line units and tag tog...

Страница 4: ...and the relays are not available with pulse features The open collectors and relays can be controlled either automatically or manually The alarm status with flashing red message will show on the disp...

Страница 5: ...mmodate under and over ranges from 1 to 23 mA The output can be reverse scaled such that the meter s high calibration value outputs 4 mA and the meter s low calibration outputs 20 mA PUMP CONTROL DPM...

Страница 6: ...inputs for instance 0 0 and 2000 0 Round Horizontal Tank Linearization This function automatically calculates the volume in a round horizontal tank with flat ends Square Root Linearization The square...

Страница 7: ...ow a 4 20 mA loop connected to the meter The first figure shows the connection without the backlight and the second shows the connection with the backlight The meter is powered by the 4 20 mA current...

Страница 8: ...t Powered by 4 20 mA loop Intensity varies with signal level PD6603 BM Top line 99FT 11IN 15 16 to 999FT 11IN 15 16 Bottom line 8 digits 9 999 999 to 99 999 999 separated by commas or 8 characters all...

Страница 9: ...set after cleared manual reset only after alarm has cleared Alarm Indication Red backlight flashing display alarm symbol symbols not available on bargraph models Bargraph segment flashes on alarm Alar...

Страница 10: ...ed to The Relay Output window is used to assign a specific task to the 2 relays such as alarm sample timer stopwatch or off A custom message that will flash every 10 seconds can also be added The 4 20...

Страница 11: ...Powered General Purpose Feet Inches Two Solid State Relays PD6603 L3N BM Loop Powered General Purpose Feet Inches 4 20 mA Analog Output PD6603 L5N BM Loop Powered General Purpose Feet Inches Two Solid...

Отзывы: