68
ADVANCED USE MANUAL DD700
3.6.12 Setup Menu/Customisation/Operating modes/MPP Mode
Also refer to the Options chapter in the user manual.
Weighing
operation
request
From key, From serial
Data
transmission
At end of weighing operation, From serial
Common port
PC
NO, com01, com02, USB device
if you choose NO, it is not possible to enable MPP function
Save tare
YES, NO
Type of
response
Standard, Terminal number, Serial number
If you select the Terminal number, you will need to set the numerical value (max. 8
digits) as explained in the Using the terminal chapter in the user manual.
Decimal
separtaror
Point, Comma
3.6.13 Setup Menu/Customisation/Operating modes/Signal Light management
(OPTIONAL)
Set the following parameters once you have set output01 red and output02 green (or vice versa):
Weight variation
Signal light timeout in seconds
The following conditions can occur:
If no weight variation is set (weight variation of 0), when the weighing operation is complete, the
green light will come on until the measured weight exceeds the minimum weighing operation (20
divisions).
In all other cases the red light comes on.
If you set a weight variation other than zero, when the weighing operation is complete, the green
light will stay on until the weight on the scale varies, in relation to the acquired weight, by an
amount that is less than the set weight variation. As soon as the weight on the scale differs from
the acquired weight by an amount that is at least equal to the set weight variation, the green light
will switch off and the red one will come on.
For example, if the acquired weight is 5000 kg and the set weight variation is 250 kg, when the
weight on the scale reaches 4750 kg because the vehicle is getting off the scale (or it reaches
5250 kg because a second vehicle is getting onto the scale), the green light goes off and the red
light comes on.
No lights are on. In fact it is possible to set a maximum time for the red and green lights to stay
on (
signal light timeout
), regardless of the set weight variation and the status of the operation.