Selecta: User Manual_______________
28
REC.TOT1 WGHTS: enables the storage of every single weighing operation of
total 1 on file;
REC.TOT1 REV: enables the storage of every single weighing operation of
(manual or network) cancelled total 1 on file (starting from rel. 5.5.15);
REC.TOT1 REV: enables the storage of every single weighing operation of total 2
on file;
REC. ON USB/DISC: determines whether the creation of storage files is to be
carried out on USB or directly on DOM;
In case the weighing operations must be stored on an FTP space, set the IP address of that space
in the "SETTINGS OTHER" menu on board instrument, item "IP USB KEY".
In case the storage must be carried out on USB/FTP,
if there is no connection
the machine starts
processing after displaying a message; the
weighing operations
are recorder on DOM and
remotely downloaded as soon as it starts processing with active connection. Every time a process
starts (even after MODIFY DATA or execution of a macro), a warning is displayed.
Every kind of weighing operation type has its own storage file which can be spotted from the file
extension (".prd" for products, ".tt1" for totals 1 and ".tt2" for totals 2);
files are “daily”
generated
, in order to avoid the creation of files too big possibly giving trouble during
opening.
The name of the files is structured to give information about the date of creation
and the number of the line gene rating it
.
The structure is the following:
"DDDYYLLL.ext"
where:
DDD = 3 digits of Julian Day (day of the year);
YY = 2 digits of the year;
LLL = 3 digits expressing the "LINE NUMBER" parameter, to be set in the
instrument "SETTINGS OTHER" menu;
ext = file extension (".prd" for products, ".tt1" for totals 1 and ".tt2" for totals 2).
2.22.3 Structure of Weighing Operations
For each kind of weighing operation, it is possible to set the parameters of the process to be
saved in the data string, in the same way as the network connection. For that reason, in the
directory have been added
"ARCHIVES \ USER \ CONFIG"
3 new files, including the
process fields
the system must add to the weighing operation string.
Files are grouped by type of weighing operation:
PRODFLD.CFG = field list of product weighing operations (download here a
sample file);
TOT1FLD.CFG = field list of total 1 weighing operations (download here a sample
file);