86
DD1050
•
false
field:
Axle stability (param_StabilitaAssi).
> Single axle weighing mode. Allows you to choose a limit value (given in the scale's unit of
measurement). This value is the tolerance margin the weight of the single axle may have.
This limit value is also used to calculate the minimum weight you wish to discriminate.
Default Value: [200]; Type: Int
field:
Average (param_Media).
> Single axle weighing mode. This parameter decides how many weight values to average. All
of the approx. 20 values/second are transmitted with average 1. Raise the average value to
lower the noise of the readings.
Default Value: [val_2]
•
1 (val_1)
•
2 (val_2)
•
3 (val_3)
•
4 (val_4)
field:
Max. Weight on axle (param_MaxPesoAsse).
> Single axle weighing mode. Allows you to choose a limit value (given in kg or better still, in
the scale's unit of measurement). If the qweight of an axle exceeds this limit value, an axle
overload will be indicated in the printout by an "*”.
Default Value: [20000]; Type: Int
field:
Use alarm (param_UsoAllarme).
> Single axle weighing mode. Activation of wheel out control. Error is indicated on the printout
if the vehicle fails to drive off the scale correctly, e.g. by steering and driving off with the
axles slanting in relation to the longitidunal line of the scale.
Default Value: [false]; Type: Bool
•
true
•
false
field:
Wheel Limit (param_LimiteRuota).
> Single axle weighing mode. Allows you to choose the limit value (given in the scale's unit of
measurement) at which the alarm trips. The alarm activates if the weight drops below the
value selected for a reasonable number of consecutive readings. Also consider the weight of
one or more persons descending from the vehicle when assessing the value to select.
Default Value: [500]; Type: Int
9.12 CbMainWeight.ConfigFields.ConfigSchema.xml
Plugin: PluginCbMainWeight
Schema: ConfigSchema
Component Name:
Customizable fields - (CbMainWeight.ConfigFields)
Category:
- (UseMode)
SubPath:
Common configuration - (RESOURCE::CbMainWeight.param_CommonConfiguration)
field:
Field management (param_Fields).
Default Value: [val_Disabilitato]
•
Disabled (val_Disabilitato)
•
Enabled (val_Abilitato)
Содержание DD1050
Страница 1: ......
Страница 2: ......
Страница 15: ...15 DD1050 I Figure10 1 1 jpg I Figure 1 3 Front panel parts display with touch screen and inverter 4 1 2 3 ...
Страница 17: ...17 DD1050 I Figure10 1 3 jpg I Figure 1 5 Spares for scale inputs and serial links 17 16 15 18 20 19 21 ...
Страница 57: ...57 DD1050 8 PROGRAMMING DIALOGUES VIA SERIAL LINKS SEE COMMUNICATIONS MANUAL ...
Страница 96: ...96 DD1050 ...