4 – TROUBLESHOOTING
31
TROUBLESHOOTING
Refer to Table 4-1 for basic troubleshooting operations. Additional information
can be found in the BilJax Model 45XA Parts and Service Manual. Contact the
BilJax Service Department with any questions or before attempting any
advanced troubleshooting operations.
Table 4-1. Troubleshooting Steps
PROBLEM CAUSE
SOLUTION
No lights on panel when
key switch is turned to the
on position.
a. Emergency
STOP
engaged.
b. Battery charge is low.
c. Battery ground or in-series cable is loose.
d. Battery main disconnect unplugged.
e. Blown
fuse.
a. Disengage
Emergency
STOP
buttons.
b. Recharge
as
needed.
c. Inspect and repair battery connections.
d. Plug in main disconnect.
e. Replace
fuse.
Hydraulic function does not
work and display window
shows an error message
a. Fault detected by safety interlock
microprocessor.
b. Boom Lift electric or electronic failure
a. Refer to Table 4-2 for error code
definition and correction.
b. Refer to Table 4-2 for error code
definition and correction.
Outrigger indicator LED
lights do not function.
a. Key switch turned to the
OFF
or platform
controls position.
b. Emergency
STOP
engaged.
c. Outriggers not deployed.
a. Turn key switch to ground controls
position.
b. Disengage
emergency
STOP
buttons.
c. Deploy all outriggers.
One or more boom controls
do not function
OR
One or more boom controls
function improperly
OR
One or more boom controls
function intermittently.
a. Key switch is turned to the
OFF
or
incorrect control position.
b. Battery charge is low.
c. Emergency
STOP
engaged.
d. Battery ground or in-series cable loose.
e. All outriggers not properly deployed.
f.
Hydraulic pump inoperative.
g. Loose
wiring
connector.
h. Valve solenoid not operating properly.
i.
Fault detected by system interlock.
j.
Broken or loose wire.
a. Turn key switch to ground or platform
controls position.
b. Recharge
battery.
c. Disengage
Emergency
STOP
buttons.
d. Inspect and repair battery connections.
e. Deploy all outriggers and level boom lift.
f.
Inspect pump; replace or repair as
needed.
g. Check wiring terminals in control box
and at valve manifold; replace or repair
as needed.
h. Clean valve solenoid and recheck
function(s); replace or repair as needed.
i.
Check display for system status. Refer
to Table 4-2 for error code definitions
and correction.
j.
Inspect wiring in control box and at
valve manifold and valve coil; repair or
replace as needed.
Содержание 45XA
Страница 1: ...OPERATOR S MANUAL 45XA AERIAL WORK PLATFORMS BOOMTM ...
Страница 10: ...BILJAX 45XA 8 NEVER jumpstart other vehicles using the boom lift batteries ...
Страница 17: ...2 BEFORE OPERATION 15 ...
Страница 31: ...3 OPERATION 29 ...
Страница 37: ...4 TROUBLESHOOTING 35 ...
Страница 43: ...5 DECAL PLACEMENT 41 ...
Страница 46: ...BILJAX 45XA RANGE OF MOTION Figure 7 1 Range of Motion 44 ...
Страница 50: ...BILJAX 45XA 48 ...
Страница 51: ...NOTES ...