Operating Manual Nr.
057-2-6-0014-R0
Page 22
Version 2021
EN
5.2
Power supply
Compressed air pump - Connect the compressed air circuit to the lifting platform.
Electric pump - Connect the electric cable to the power grid using the plug (not supplied),
according to the regulations in force in the Country of use. The socket must be grounded.
CAUTION:
In the electronic or electro-hydraulic version, the lifting platform is
equipped with an electronic board which transforms the low-voltage current to
prevent the electrocution risk. A fuse calibrated on the amperage of the stable
230V power supply is located inside this board.
It is forbidden to replace/tamper with this fuse with one of a higher
resistance/amperage.
5.3
Commissioning
The tests to be carried out before using the machine have the task of verifying that the
mechanical and electrical installation (in the electro-hydraulic pump versions) has been
carried out correctly and there are no breakages or damages which could compromise the
proper functioning and the performance of the machine.
Make sure:
There are no signs of obvious breakage or damage to the mechanical structures;
The mechanical safeties previously described are functioning;
The connecting pipe between the pump and the hydraulic cylinder does not have any
cracks and is in good condition;
All the Seeger ring clips placed on the pins are installed correctly.
In the versions equipped with electro-hydraulic pump, also check that:
The electric cable and plug protections (not supplied, but to be installed by the User in
compliance with the country's regulations) are in perfect condition;
The power plug is properly inserted in the socket;
The electrical power wiring between the pump and the socket is well positioned, not
twisted, does not interact with the passage routes or the storage spaces and does not
interfere with other machineries;
The connection to the electrical system is suitable for power and amperage in order to
power the electro-hydraulic pump (refer to the data on the plate shown on the lifting
platform).
Carry out the connection following the instructions contained in the Manual supplied with the
pumps.
TECHNICAL DATA OF THE ELECTRIC MOTOR:
Use voltage: 220/230 V. Frequency: 50 Hz. Absorbed power: 1kW
Use voltage: 110/115 V. Frequency: 60Hz. Absorbed power: 1kW