Annual Preventive Maintenance
Note: Actual installation setup may differ from picture.
To be performed annually (see “Maintenance Checklist” in back of manual):
1. Check for the presence of the safety cable and shackle. The cable should be wrapped around the I-beam/angle irons, leaving as
little slack as possible. The shackle should be securely tightened and located on the topside of the I-beam/angle irons.
2. Ensure all mounting bolts (12x) are present and torqued to 40 ft·lb
(54.2 N·m). Ensure the lower cable is between the brackets of
the lower yoke.
3. Inspect motor terminations inside junction box and tighten if necessary.
4. Check all connections in the fan controller and tighten as needed.
5. Check gear reducer for oil leakage. If leakage is present, contact Customer Service at 1-877-BIG-FANS.
6. Ensure all bolts (20x) securing airfoils to fan are present and torqued to 29 ft·lb
(39 N·m).
7. Ensure airfoils are secured to one another by airfoil retainers (10x).
8. Ensure bolts securing hub safety clips are present and torqued to 29 ft·lb
(39 N·m).
Additional Considerations
•
Verify proper fan rotation. The fan should be turning counter-
clockwise when viewed from the floor.
•
Dust airfoils, motor, and motor housing. If desired, use a gentle
cleaner or degreasing agent to polish the foils. Do not use Clorox®
or other chlorine based cleaners! This could result in the release of
toxic/fatal fumes.
WARNING: Do not operate a fan with
missing or damaged components.
Please contact Customer Service at
1-877-BIG-FANS.
5
8
6
7
45
WWW.BIGASSFANS.COM ©2011 DELTA T CORP. DBA BIG ASS FAN CO. ALL RIGHTS RESERVED
8’ - 24’ POWERFOIL® X
User Servicing
Please take a few moments each year to perform the following preventive maintenance inspection to your fan to ensure its safe and
efficient operation. If you have any questions, contact Customer Service at 1-877-BIG-FANS. If you require assistance, contact Field
Service at 1-877-BIG-FANS to schedule a visit.
WARNING: Risk of fire, electric shock, or injury to persons during cleaning and user-maintenance! Disconnect
the appliance from the power supply before servicing.
WARNING: Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning device (such as a tag) to the service panel.
WARNING: When service or replacement of a component in the fan requires the removal or disconnection of a
safety device, the safety device is to be reinstalled or remounted as previously installed.
4
Содержание 8'-24' Powerfoil X
Страница 1: ...8 24 Powerfoil X INSTALLATION GUIDE...
Страница 53: ...47 WWW BIGASSFANS COM 2011 DELTA T CORP DBA BIG ASS FAN CO ALL RIGHTS RESERVED 8 24 POWERFOIL X Notes...
Страница 55: ......
Страница 63: ......
Страница 65: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......
Страница 72: ...170511 REV B 2425 Merchant Street Lexington KY 40511 1 877 BIG FANS 1001120101...