Installation, Operation and Maintenance Manual
VCIOM-01249-EN Rev. 0
73
Set-Up Routines
Section 9: Set-Up Routines
9.2.1
Sample Configuration Procedure
Tag name
•
Move the local selector to OFF and then simultaneously press OPEN and STOP.
Select the language and enter the password according to the instructions (see
“Entering the set-up mode”). When the message displayed is “SET-UP MODE OK?”
press YES.
•
Press NO to scroll the list of available menus and then press YES to select valve
data menu.
•
Press NO to scroll the list of available routines and then press YES to select
Tag name.
•
Press YES if the 1st character of the string is correct. Press NO to scroll the list of
available characters. Press YES to select the desired character.
•
Enter up to 28 characters. Enter a blank character, and “
” as end of string.
The configuration of all other valve data items is made in the same way, by selecting the
relevant item from the list of available routines.
9.3 Maintenance
A large amount of data is stored in the actuator memory and is available for future analysis
or to assist the operator in the maintenance program. The maintenance menu also includes
the set password routine and the possibility to modify or start the maintenance functions.
The following data are available:
•
set password
•
clear alarm log
•
set torque reference
•
set curve reference
•
clear recent data log
•
set maintenance date
•
set data logger
➞