38
18
Ignition and detection electrodes,
burner and spark generator
18.1
Function
Three electrodes are fitted on the fan---burner group.
Two of them, fitted on the right side of the fan---burner
group
A
, are the ignition electrodes
B
and are con-
nected to the spark generator
C
.
On the left side is the detection electrode
D
and it de-
tects the presence of the flame.
J
G
F
H
J
I
D
I
A
I
B
C
K
K
Fig. 18.1
The burner
E
is fitted on the rear of the fan---burner
group A.
E
Fig. 18.2
18.2
Removal of the Ignition and detection
electrodes
Warning: isolate the boiler from the mains
electricity supply before removing any
covering or component.
1
Remove all the case panels and the sealed
chamber lid (see section 2) .
2
Disconnect the ignition electrodes connector
F
and the earth wire
G
from the spark generator C
(Fig. 18.1) and disconnect the detection elec-
trode connector
H
.
3
Unscrew the screws
I
and remove the ignition
electrodes B and the detection electrode D
(Fig. 18.1).
4
Assemble the Ignition and detection electrodes
carrying out the removal operation in reverse or-
der.
When reassembling the ignition electrodes be sure
to connect correctly the wires to the spark genera-
tor (see Fig. 18.3)
C
earth wire
ignition electrodes
wire
Fig. 18.3
18.3
Removal of the burner
Warning: isolate the boiler from the mains
electricity supply before removing any
covering or component.
1
Remove the air box and the fan (see section 17.2)
2
Remove the Ignition and detection electrodes
(see section 18.2).
Содержание RIVA ADVANCE HE M110B.24SM/C
Страница 49: ...Short spare parts list 47 P5 1 5 3 4 2 6 9 7 14 16 20 19 21 8 11 15 17 10 12 13 18 ...