HANDBOOK AND SERVICE LOG

MODEL

12/19

20/25

26/30

50/70

75/95

BOILER SERIAL NUMBER:

Summary of Contents for Tuscan 12-19

Page 1: ...HANDBOOK AND SERVICE LOG MODEL 12 19 20 25 26 30 50 70 75 95 BOILER SERIAL NUMBER ...

Page 2: ... use the very best materials and engineering practice in the construction of our boilers your boiler will provide many years service Properly engineered product doesn t require reams of small print to and get out clauses our terms and conditions very concise 1 Register the boiler with Hounsfield Boilers Ltd You can do this on line via our web site or by returning the registration form enclosed wit...

Page 3: ... in this document Please ensure your boiler warranty is registered with Hounsfield Boilers Ltd Our warranty is industry leading however we do ask that you follow our the terms and conditions Our best sales generator is word of mouth please pass the additional brochure supplied with your boiler to a friend or neighbour Kind regards Andrew Hounsfield andrew hounsfieldboilers co uk T 01449 722461 ...

Page 4: ...he boiler to cool down then press the reset button Lockout neon and lockout reset button The amber neon is illuminated when burner ignition has failed this is a safety feature To reset the burner wait for two minutes then press the burner reset button Burner reset button Vent port Priming the burner if you run out of oil Use the 4 mm allen key located inside the boiler casing Slacken the vent port...

Page 5: ...but will require commissioning after installation 2 A setting gauge is supplied with every boiler to check critical dimensions 3 To change the factory set output a different gauge is required see table DIFFUSER SETTING NOZZLE FACE TO REAR OF DIFFUSER HEAD SETTING HEAD ADJUSTMENT SERVICE ENGINEER S INFORMATION SETTING GAUGE 16KW BOILER MODEL 12 19 HEAD SETTING DIFFUSER SETTING ELECTRODE GAP 2 MM EN...

Page 6: ...1 BS0072 BS0073 BS0074 BS0075 BS0076 BS0077 BS0078 BS0079 BS0080 BS0081 BS0082 BS0083 BS0084 BS0085 HEAD SETTING 0 1 MM 25 5 26 5 28 29 5 31 5 32 33 36 35 8 36 27 28 29 5 31 5 34 5 36 7 DIFFUSER SETTING 0 1 MM 2 2 2 2 2 2 2 3 3 3 2 2 2 3 3 3 NOMINAL AIR SETTING 1 1 2 1 6 2 3 2 5 2 8 3 2 5 6 6 5 2 2 5 2 8 4 4 5 5 5 SMOKE NO 0 0 0 0 0 CO2 11 5 11 5 11 5 11 5 11 5 CO PPM 10 5 9 7 8 7 5 9 8 5 8 7 9 5 ...

Page 7: ...gnostics mode To deactivate press the button for 1 second or remove control box to reboot 8 Flickering red Diagnostics mode for connection to a computer When a solid red light is illuminated you can get information about what has caused the problem by pressing holding the reset button for 3 seconds The number of flashes is is repeated with a pause between 9 2 flashes No flame when ignition safety ...

Page 8: ...SERVICE LOG YEAR DATE YEAR DATE 1 11 2 12 3 13 4 14 5 15 6 16 7 17 8 18 9 19 10 20 Service engineer s contact details Business contact name Mobile Tel Email LI0020 ISSUE 1 ...