10
5
Condensing heat exchanger
5.1
Function
The Condensing heat exchanger
A
in Fig. 5.1 has the
function of transferring heat produced from combus-
tion of the gas and from the flue exhausted gas to the
water circulating in it.
A
B
C
Fig. 5.1
By reducing the combustion products temperature, the
latent heat of the vapour is transferred to the water cir-
cuit, allowing an extra gain of useful heat.
The condensed vapour is then drained through the
condensate trap
B
and the draining pipe
C
.
5.2
Removal
Warning: isolate the boiler from the mains
electricity supply before removing any
covering or component.
1
Disconnect the flue system from the boiler.
2
Remove the fan group (rubber pipe, gas pipe) fol-
lowing the instructions from 1 to 6 in section 17.2.
3
Disconnect the detection electrode connector
D
,
the ignition electrodes connector
E
and the earth
wire
F
.
4
Disconnect the fan connector
G
by pressing the
plastic hook placed on the side of the connector
(Fig. 5.2).
5
Unscrew the nuts
H
(Fig. 5.2).
6
Remove the fan---burner group
I
.
7
Empty the primary circuit of the boiler.
8
Remove the clips
J
(Fig. 5.2).
9
Loosen the connection
K
and slightly move the
pipe
L
upwards, turn it towards left (Fig. 5.2) and
then move the pipe downwards freeing it from the
Condensing heat exchanger.
H
I
F
E
I
J
G
D
K
L
M
N
Fig. 5.2
10
Loosen the connection
M
and slightly move the
pipe
N
upwards, turn it towards left (Fig. 5.2) and
then move the pipe downwards freeing it from the
Condensing heat exchanger.
Q
O
P
R
Fig. 5.3