- 28 -
USE
USEFUL ADVICE
3.8 Remote anomaly code
If the boiler is connected to remote (option-
al), a code that indicates a boiler anomaly is
displayed in the centre of the display.
The anomaly in progress is indicated by a
numeric code followed by the letter
E
.
The table summarises the possible codes
displayed on the remote.
Anomaly
Code
Lack of burner ignition
E01
Safety thermostat lockout
E02
General lockout
E03
Lack of circulation pump
E04
Faulty fan control system / air
pressure / flue thermostat
E05
Faulty c.h. temp. probe NTC1
or NTC2
E06
Faulty d.h.w. temp. probe
NTC
E07
Faulty external temp. probe
NTC (with K set)
E08
Flame detection error
E11
Lack of circulation T >105°C
E14
3.9 Flue probe
The flue probe 22 and safety thermal fuse
28 indicated in Fig. 3.8 are a safety device.
The flue probe 22 intervenes when the flue
temperature exceeds 110°C placing the
boiler in safety block switching it off.
To reset normal boiler functioning, just press
the 15 (Fig. 3.6) key.
If flue probe 22 does not intervene and,
therefore does not send the boiler into se-
curity lockout, thermofusible 28 enters into
function as a further safety measure.
This component sends the boiler into se-
curity lockout when the flue temperature
reaches 167°C.
To restore the normal operation of the boil-
er, contact the Authorized Service Centre.
Fig. 3.8
22