Installation & Operating Instructions
BIANCO B range of submersible pumps is suitable for small to medium dewatering and or
wastewater applications. The Vortex pumps (VA) are able to pump soft solids in suspension. The
KA cutter pump has a impeller with an edged tungsten tip and a grinding plate to assist with
cutting of fibrous materials.
The G grinder pump consists of a high chrome impeller and grinder which can grind soft solid
materials in sewage.
Dewatering Pumps: B10A, B15A, B25A, B40A, B42A, B75A
Vortex Pumps: B15VA, B25VA, B40VA, B75VA
Cutter Pump: B75KA
Grinder: B120G
Voltage: 240V 50Hz Single Phase
Submersible pumps are very quiet and are ideal for applications within residential areas for storm
water pits, basements, etc
Suitable Fluids
The Cutter (K) models are suitable for pumping soft solids in suspension. The Cutter and Grinder
(G) pumps are also suited to pump soft string-like materials such as hair, lint, straw etc. Grinder
models can pump cloth, rubber gloves, etc. The cutter and grinder pumps should not pump hard
solids as these will damage the pump face.
Pumps are
not to be used
for pumping flammable or corrosive fluids.
Installation
The BIANCO B series pumps are completely submersible up to 10 metres and can be installed
on a level surface in a stationary position connected to either fixed pipe work or flexible hose.
Never remove or lift a pump by the power cable. Instead connect a rope to the handle during
installation.
External float switch versions should be placed in a sump of a suitable size so that the float
switch is not restricted or could be caught in the up position. The float switch must be installed so
that the ON and OFF operating points can be easily reached, and that the float switch head is not
too close to the latching holder which prevents correct operation. The float switch must not touch
the base of the sump or tank which will prevent the pump turning off.
All pumps must not be allowed to run dry.
Motor Cooling
All models rely upon water flow around the motor for correct motor cooling.
All models are suitable to operate partially submerged for periods up to 10 minutes.
Operating at very low flows caused by high heads or restricted pipe work may cause motor over
heating.