background image

   page 8 

 

 

 

 

 

        

Installation and Operation Guide 

 

 

 

           

                 PREZONE2

Back Panel Wiring and Connections (continued)
Standby Modes

The PREZONE2 has two standby modes: Manual and Auto. 

Manual Standby Mode

If auto standby is set to DISABLED on the back panel, push the on/standby 

button to enter standby mode. When in standby mode, the front panel on/

standby button will not be lit. The webapp will indicate the device is in 

standby mode and the displays of any connected DIWAC wall panels will 

turn off.
The device will exit standby mode if:
•  Any front panel button is pushed
•  Emergency Mode is activated
•  The back power switch is cycled 

on/off (or mains power is otherwise 

interrupted)

NOTE:

 the device will enter standby mode 

by pushing the front panel standby button, 

regardless of the auto standby setting.

Auto Standby Mode

See Figure 10. If auto standby is set 

to ENABLED on the back panel, the 

PREZONE2 will enter standby if no 

audio is present (less than -40dB) on 

all selected inputs for 10 minutes. The 

device will not enter standby if Emergency or Paging modes are active.
When auto standby is active, the front panel On/Standby button LED will 

pulse on and off. Any connected DIWAC wall panels will indicate that auto 

standby is active.
The device will exit auto standby mode if:
•  An audio signal above -40dB is applied to a previously-selected input
•  Any front panel button is pushed (including the On/Standby button)
•  A connected DIWAC wall panel button is pushed
•  Emergency or Paging Mode is activated
•  The back power switch is cycled on/off (or mains power is interrupted)
•  An external SET command is received via RS232

Network Connections

The PREZONE2 may be operated via the built-in webapp by connecting the 

PREZONE2 to a controlling device via a network connection.

The PREZONE2 will automatically obtain an IP address and configure. In a 

routed network, the PREZONE2 will obtain an IP address via DHCP. In a switch 

network or direct connection to a controlling device, the PREZONE2 will auto-

generate a link-local address.
Factory default hostname is 'prezone2,' which may be changed in the webapp 

(connecting via hostname is the most reliable way to connect to the PREZONE2)
Further information on PREZONE2 connections and Zero Network Configurations 

can be found on 

support.biamp.com

.

Connect to the Webapp via Switched or Routed Network

The PREZONE2 webapp may be accessed via PC/Laptop or mobile device, 

depending on the network configuration. PREZONE2 uses a standard called 

‘Zero Configuration Networking,’ which allows the device to fully configure itself.
 

1. 

See Figures 11-13 for connection options. Use the configuration suitable 

to design and network requirements.

2. 

Once the PREZONE2 is connected in one of the configurations shown, 

open a web browser on a PC or mobile device and enter the hostname in 

the address bar. 

a.  Regardless of the connection type (wired/wireless), the controlling 

device must be on the same network infrastructure as the PREZONE2. 

3.  If a DNS server is available, enter the hostname in the browser as follows: 

"prezone2/". Press enter.

4.  If no DNS server is available or the PREZONE2 is connected to a 

switched network, use mDNS to connect by entering the hostname in the 

browser bar as follows: "prezone2.local/". Press enter.

5.  Another option to connect is by entering the IP address directly into the 

browser bar (use of a 3rd party application can be used to find the IP 

address).

6.  The PREZONE2 webapp will now be available via the connected device. 

Multiple devices may connect to the PREZONE2 simultaneously. 

NOTE:

 Android devices do not allow ".local" searches from the browser. If using an Android device, 

use a local DNS server to resolve the hostname to the IP address. If no DNS server is available, 

enter the IP address directly into the web browser bar.

Figure 10.

 Auto Standby Switch

Содержание PREZONE2

Страница 1: ...ric shock the external wiring connected to the terminals marked with class 2 wiring requires installation of class 2 wiring by an authorized trained person or by using ready made leads or cords This unit has NOT been designed for use in mobile applications such as mobile discobars mobile PA systems live bands and audio rental systems Using it in such applications will lead to product damage and sa...

Страница 2: ...utton controls for two distinct zones of audio outputs and an array of LEDs that give status of numerous functions of the device Rotary encoders volume controls feature LED indication of the actual volume level Adhesive labels may be applied to indicate zone sources and outputs 1 Standby Initiates or disables manual standby mode Indicates status of standby mode 2 Zone 1 Volume Control Rotary volum...

Страница 3: ... panel LED PAG the PAG indicator on the webapp and a RS232 notification Activating the paging mode will also activate the priority output of the selected zone s 3 MIC A Input MIC A input has the 3rd highest priority of all inputs The input connection accepts a balanced microphone or line level audio signal via the Euroblock connector and a stereo line level via RCA connectors A pushbutton allows s...

Страница 4: ...r cable 11 Auto Standby Enables Disables auto standby mode 12 Priority Out 3 pin Euroblock connector with two 24 VDC priority signals Active when either the Emergency Input or Paging is active to the zone connected Overides external volume controls present on speaker lines so emergency or paging messages are audible regardless of physical volume control status 13 RS232 3 Pin Euroblock connector th...

Страница 5: ...ts on the back panel Wiring Emergency Input 1 See Figure 2 Connect a balanced 0 dBV line level emergency input audio signal to the Euroblock connector 2 If available connect the emergency contact to the mute all connection The contact must be potential free a relay or switch contact that does not carry any voltage 3 Alternatively activate the VOX circuitry by turning the VOX control until there is...

Страница 6: ... activated the VOX circuit will attenuate all lower priority sources MIC B Input 1 4 by 30 dB in the zone s where MIC A is enabled 9 Volume may be set using the front panel level control MIC Input A or B may be activated by pressing the respective MIC A or B select switch on the front panel Wiring Inputs 1 4 1 See Figure 6 Connect source inputs as required Input 1 has Euroblock connectors that acc...

Страница 7: ...o an individual device with CAT5e or better cable 2 Once connected users have several options to access a fully responsive webapp to operate the PREZONE2 See Network Connections for more information on network configuration and accessing the webapp control page Wiring Priority Out 1 See Figure 9 Connect the 3 pin Euroblock to the override relay in any line in volume controls wired in the loudspeak...

Страница 8: ...ddress and configure In a routed network the PREZONE2 will obtain an IP address via DHCP In a switch network or direct connection to a controlling device the PREZONE2 will auto generate a link local address Factory default hostname is prezone2 which may be changed in the webapp connecting via hostname is the most reliable way to connect to the PREZONE2 Further information on PREZONE2 connections a...

Страница 9: ...IP address Figure 12 shows a direct connection from the PREZONE2 through the router and wireless connections of various devices PREZONE2 will auto configure and automatically obtain an IP address Figure 13 shows a direct connection from the PREZONE2 to a PC via Ethernet This connection does not require any manual IP settings link local both devices auto negotiate Figure 13 Direct Ethernet Connecti...

Страница 10: ...us of clipping paging and emergency mode status 2 MIC A and B Controls The MIC A and B rotary dials control the level of the respective microphone input of the zone selected The loudspeaker icon in the middle of the dial turns the microphone on or off 3 Line Level Control This rotary level control adjusts the volume of the selected source The loudspeaker icon in the middle of the dial turns the so...

Страница 11: ...ume Limits Allows adjusting minimum and maximum level controls for MIC A MIC B and Line music levels for each zone via a volume limit slider There must be a minimum 10 difference between the minimum and maximum volume levels 5 Password A password can be added to limit access to the settings page 6 Factory Reset This allows a full factory reset of the device All settings will be erased and returned...

Страница 12: ...mand that changes the same setting Test Command Examples Text Command Action Response set zone 2 selected input 3 CR Selects a source in Zone 2 set zone 1 input volume 60 CR Changes the audio level in Zone 1 set zone all mica inc volume 5 CR Increments the MIC A level in both zones get zone 2 micb onoff CR Checks mute status of MIC B in Zone 2 Response will be ON CR or OFF CR get system info CR Ge...

Страница 13: ... Guide PREZONE2 PREZONE2 Block Diagram Figure 17 below gives a signal flow block diagram of the PREZONE2 The key at the bottom right shows which blocks are located on the front and back panels respectively Figure 17 Signal Flow Diagram ...

Страница 14: ...ormation contained in this manual was complete and accurate at the time of printing However due to ongoing technical advances changes or modifications may have occurred that are not covered in this manual The latest version is available at www biamp com FEB 2020 CONTACT US Email support biamp com Web support biamp com ...

Отзывы: