PA-common parameters list:
No.
Name
Function
Default
Range
PA-2
Operation mode
selection
0: Self-running (Triggered by
pulse signal. When the pulse
signal is turned on, the motor
starts to run according to the
parameter settings of PA-45 ~
PA-53; when it is off, the motor
stops running)
2
0~3
1: Open loop mode (run
without encoder line)
2: Servo mode 0
3: Servo mode 1
PA-4
Positional accuracy
2
1~65535
encoder
pulses
PA-6
Electronic gear ratio
numerator
4000
1~65535
PA-7
Electronic gear ratio
denominator (pulse
per round)
When PA-6 is set to 4000,
PA-7 value is equivalent to the
number of pulses required for
one round of the stepper motor
(microstep).
1600
1~60000
PA-8
Encoder resolution
4000
4000
PA-9
Tracking error alarm
threshold
This value can be changed
based on actual need
5000
0~65535
encoder
pulses
PA-10 Current loop Kp
1817
0~65535
PA-11 Current loop Ki
50
0~65535
PA-12 Current loop Kc
256
0~65535
PA-13
Alarm clear signal
(CLR-A) function
selection
0 CLR-A to clear deviation
alarm;
1 CLR-A to change the
direction of the motor rotation
0
0/1
PA-14
Enable (MF)
function setting
1
MF is used as a general
motor release signal
0 MF as a pulse blocking
function
1
0/1
PA-15
Enable (MF) level
selection
0 The default set is: the driver
respond to pulse command
when MF is not connected
1 Respond to pulse
command need 5V MF
signal
0
0/1
PA-16 Alarm signal (ALM)
1 Alarm output ALM normally
1
0/1
Bholanath
COMMITTED TO PRECISION
®
www.bholanath.in
14