D812034 00100_03
VISTA
SW
SXL
- 13
ENGLISH
INSTALLATION MANUAL
PARAMETER
DEFINITION
MIN. MAX. DEFAULT
CUSTOM
DESCRIPTION
16
Auxiliary input 2
configuration
0
12
1
0 = Input configured as Disabled opening
1 = Input configured as Emergency opening
2 = Input configured as Interlock door with priority
3 = Input configured as Interlock door without priority
4 = Input configured as Lock Release Feedback
5 = Input configured as Lock release
6 = Input configured as Single Command with Master/Slave operating mode
7 = Input configured as Standby. If activated, it sets the door to standby only
with the door in the closed position.
8 = Input configured as wake up from Standby. If activated, it restores
operation following a Standby
9 = Input configured as step-by-step command, meaning that with a pulse
the door opens and stays open, standing by for another pulse to close, again
with the use of Int. Radar or Ext. Radar
10 = input configured as Temporary Stand By. If activated, the door is in stand
by and therefore the closing movement is spring-loaded. If deactivated, the
door works normally.
11 = Input configured as manual operation. If active, the operation of the
selector in the head is disabled.
12 = Input configured as Stop Closed operation. If active, the operation of the
selector in the head is disabled.
17
Auxiliary output 1
configuration
0
5
0
0 = Output configured as Sensor supervision
1 = Output configured as Interlock
2 = Output configured as Door State open.
3 = Output configured as Door State closed.
4 = Output configured as Fault
5 = Output configured as Lock command repeat
18
Auxiliary output 2
configuration
0
5
1
0 = Output configured as Sensor supervision
1 = Output configured as Interlock
2 = Output configured as Door State open.
3 = Output configured as Door State closed.
4 = Output configured as Fault
5 = Output configured as Lock command repeat
19
Not used
0
0
0
Not used, must be kept at = 0
20
Safety disabling angle
during opening [%]
0
40
0
Safety disabling angle during opening, percentage of total travel
21
Master/Slave Connection
Opening Time Lag [s]
0
100
0
Slave motor opening delay time with respect to master motor. 100ms
increments
22
Master/Slave Connection
Closing Time Lag [s]
0
100
0
Master motor closing delay time with respect to slave motor. 100ms steps
23
PHOT OPEN input
polarity
0
1
1
0 = N.O. Normally open
1 = N.C. Normally closed
24
PHOT CLOSE input
polarity
0
1
1
0 = N.O. Normally open
1 = N.C. Normally closed
25
KEY input polarity
0
1
1
0 = N.O. Normally open
1 = N.C. Normally closed
26
RADAR EXT input
polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
27
RADAR INT input polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed
28
AUX-IN 1 input polarity
0
1
0
0 = N.O. Normally open
1 = N.C. Normally closed