5) Functions controlled by the trimmers
TW.PED

Adjusts the working time of the pedestrian access gate (motor
2) or the partial working time of a sliding gate with both pedes-
trian and vehicular access.

TW

Adjusts the working time both during opening and closing.

TCA

Adjusts the dwell time after which the gate re-closes automati-
cally.

T.DELAY Adjusts the delay time on closing of motor 2.

6) LED functions
The Rigel 4 control unit is equipped with a series of LEDs which detect any
system malfunctions.
LINE

(DL1)

Stays on in the presence of the mains supply and when
the fuse F2 is in perfect working order.

START I (DL2)

Lights up when an internal start command is given.

START E (DL3)

Lights up when an external start command is given or
when the first channel of the receiver is activated.

PED

(DL4)

Lights up when a start command for the pedestrian ac-
cess is given.

OPEN

(DL5)

Lights up when a manual opening control is given.

CLOSE

(DL6)

Lights up when a manual closing control is given.

STOP

(DL7)

Switches off when a block command is given.

PHOT

(DL8)

Switches off when the photocells are not aligned that is
when obstacles are detected.

BAR

(DL9)

Switches off when the sensitive edge is activated.

SWO1

(DL10) Switches off when the gate (motor 1) reaches its com-

plete opening position provided that it is equipped with
a limit switch.

SWC1

(DL11) Switches off when the gate (motor 1) reaches its com-

plete closing position provided that it is equipped with a
limit switch.

SWO2

(DL12) Switches off when the gate (motor 2) reaches its com-

plete opening position provided that it is equipped with
a limit switch.

SWC2

(DL13) Switches off when the gate (motor 2) reaches its com-

plete closing position provided that it is equipped with a
limit switch.

(DL14) Direction indicator LED: lights up when the gate is clos-

ing.

M1

(DL15) Lights up when motor 1 is activated (on opening or clos-

ing).

M2

(DL16) Lights up when motor 2 is activated (on opening or clos-

ing).

After having connected the control unit to the mains with the jumpers pre-
wired between the terminals, see figure 2, make sure that it works perfectly
by checking if the following LEDs light up: LINESTOPPHOTBARSWO1,
SWC1SWO2SWC2.
This fast check is recommended before installation in order to discover any
malfunctions of the control unit.

7) SSR4 traffic light board (on request)
This board is only supplied for the Rigel 4 control unit.
SSR4 permits to manage two traffic lights with two lights each, one usually
red and one green, which operate according to the usual logic for automatic
gates. In addition, some other options are available that can be set using
the Dip-switches provided in the SSR4 board.
The gate as well as the traffic light can be controlled by means of two com-
mands:

internal START (given when the gate is closed) which not only opens
the gate but also switches on the red light on the outside and the green
one on the inside when the gate is open.

external START (given when the gate is closed) which not only opens
the gate but also switches on the red light on the inside and the green
one on the outside when the gate is open.

During the opening and closing manoeuvres the two red lights are illumi-
nated.

IMPORTANT NOTE

Provide signals inviting to limit the speed and

to proceed slowly.

For a correct command sequence of the traffic light system, observe the
following procedures:

Position the traffic light 2 inside with respect to the gate and the traffic
light 1 outside the gate (see figure 3).

Activate the functions BLI2-step logic and pre-alarm (Dip 2, Dip 6,
Dip 7 all to ON)  provided on Rigel 4.

The only command to gain access from the outside must be the exter-
nal START
 (already present on the first channel of the receiver).

For installations with traffic lights not visible from each other it is
recommended to use the special microprocessor of Rigel 4 in which the
function of the Dip 2 of Rigel 4 becomes:
ON- Impulse blocking device active on opening.
OFF- Impulse blocking device active on opening and during the TCA
phase (if TCA on).

Terminal board connections:
1) phase
2) red light of traffic light 1
3) red light of traffic light 2
4) green light of traffic light 1
5) green light of traffic light 2

Dip-switch 1 Inhibits the blinking function at movement start
ON - Inhibits the blinking function at movement start
OFF - Activate the blinking function at movement start (operation time 5
sec).
Dip-switch 2 Permanent red light with gate closed
ON - Activates the red lights, when the gate is closed
OFF - Switches off the lights when the gate is closed.

Signals provided by the board:
Red and green LEDs for traffic light 1 and traffic light 2.
Luminous signal for each traffic light:
Green light: access permitted - fixed red light: access not permitted - Flash-
ing red light: gate movement start; access not permitted.
N.B.: The movement reverse on closing does not enable the green light;
before giving the Start command it is necessary to wait until the gate is
completely closed.

www.metalines.com

[email protected]

Содержание Rigel 4

Страница 1: ...s bft it BFT S r l ITALIA BFT DEUTSCHLAND BFT U K BFT FRANCE BERMATIC BFT S L Poligono GARONA NAVE Q 19200 AZUQUECA DE HENARES GUADALAJARA Tel 949 263200 Fax 949 262451 BFT ESPAÑA Parc Club des Aygalades 35 bd capitaine GEZE 13333 MARSEILLE Cedex 14 Tel 04 91 98 13 82 Fax 04 91 98 11 27 D811208 02 09 98 Ver 02 I ISTRUZIONI INSTRUCTIONS INSTRUCTIONS MONTAGEANLEITUNG INSTRUCCIONES CENTRALINA DI COMA...

Страница 2: ...2 RIGEL 4 www metalines com sales metalines com ...

Страница 3: ...ale JP4 13 14 Uscita 24Vac 3W max per luce spia di segnalazione cancello aperto Questa spia è spenta a cancello chiuso lampeggia in chiusura e rimane accesa con cancello aperto o in fase di apertura 15 16 Uscita 24Vac 6W max per alimentazione accessori 17 18 Uscita per elettroserratura a scatto 12Vac 10W max 19 20 Ingresso antenna scheda radioricevente 19 segnale 20 calza 21 22 Uscita secondo cana...

Страница 4: ...to in apertura o chiusura M2 DL16 Si accende quando il motore 2 è attivato in apertura o chiusura Collegando la centralina alla rete di alimentazione come viene fornita con ponti precablati tra i morsetti figura 2 questa funziona regolarmente se si accendonoiseguentiled LINE STOP PHOT BAR SWO1 SWC1 SWO2 SWC2 Questo rapido controllo è consigliato prima di effettuare l installazione in opera onde ri...

Страница 5: ...a input 19 signal 20 braiding 21 22 Output of second radio channel if 2nd channel receiver installed JP5 23 24 Start command n o START I for traffic light 24 25 Start command n o START E for traffic light 26 27 Pedestrian gate start command 28 30 Open command n o 29 30 Close command n o 31 33 Stop command n c 32 33 Photocell input safety circuit n c 33 34 Second safety circuit Safety edge 35 36 Op...

Страница 6: ... to manage two traffic lights with two lights each one usually red and one green which operate according to the usual logic for automatic gates In addition some other options are available that can be set using the Dip switches provided in the SSR4 board The gate as well as the traffic light can be controlled by means of two com mands internal START given when the gate is closed which not only ope...

Страница 7: ...Vac 3W max pour lampe de signalisation portail ouvert Cette lampe elle reste éteinte à portail fermé elle clignote à portail en fermeture et elle s allume à portail ouvert ou en ouverture 15 16 Sortie 24Vac 6W max pour alimentation accessoire 17 18 Sortie 12Vac 10W max pour électroserrure à encliquetage 19 20 Entrée antenne pour carte réceptrice 19 signal 20 gaine 21 22 Sortien o deuxièmecanalradi...

Страница 8: ... activé en ouverture ou en fermeture M2 DL16 S allume lorsque le moteur 2 est activé en ouverture ou en fermeture En connectant la centrale à la ligne d alimentation comme elle est fournie avec ponts précâblés entre les bornes figure 2 celle ci marche régulière ment si les leds suivantes s allument LINE STOP PHOT BAR SWO1 SWC1 SWO2 SWC2 Ce contrôle rapide est conseillé avant d effectuer l installa...

Страница 9: ...ffen 24V Max 3W Leuchtet bei Öffnung und Tor offen blinkt in Schliessung und erlischt bei Tor zu 15 16 Ausgang 24Vac 250mA für Stromversorgung der Zusatzeinrich tungen 17 18 Elektroschloss Türöffner ECB 12Vac Max 10W Dauer bei Betätigung ca 3s 19 20 Antennenanschluss 19 Signal 20 Abschirmung 21 22 Ausgang für den 2 Funkkanal wenn im Funkempfängersteckplatz auf der Steuerung ein 2 Kanal Funkempfäng...

Страница 10: ...or 1 Klemme 40 DL14 Richtungs Led Leuchtet in Schließrichtung zuständig für beide Antriebe M1 DL15 LeuchtetwennMotor1inBetriebist beiÖffnungoderSchlie ßung M2 DL16 LeuchtetwennMotor2inBetriebist beiÖffnungoderSchlie ßung Wenn die Steuerung mit den bereits bei der Lieferung überbrückten Klemmen Abbildung2 andasStromnetzangeschlossenwird kanndereinwandfreieBetrieb an folgenden LED abgelesen werden L...

Страница 11: ... la ultima actividad de la central de mandos JP4 13 14 Conexión luz de aviso de cancela abierta Se enciende en abertura y con cancela abierta parpadea en cierre y se apaga con cancela cerrada 15 16 Salida para alimentación accesorios 24Vac 6W max 17 18 Salida para electrocerradura a disparo 12Vac 10W max 19 20 Entrada antena para radiorreceptor 19 señal 20 trenza 21 22 Salida segundo canal radio n...

Страница 12: ...ado en apertura o cierre Conectando la central a la red de alimentación como llega de fábrica con puentes precableados entre los bornes figura 2 ésta funciona regularmente si se encien denlossiguientesleds LINE STOP PHOT BAR SWO1 SWC1 SWO2 SWC2 Es aconsejable llevar a cabo este rápido control antes de efectuar el montaje para detectar eventuales anomalías de funcionamiento en la central 7 Tarjeta ...

Страница 13: ...JP4 JP5 JP5 F1 F2 1 2 M1 JP2 RICEV RIGEL4 TRAFFIC LIGHT JP3 LINE TW PED BFT RIGEL4 TW TCA T DELAY 1 2 3 4 5 6 7 8 910 ON DIP function 1 FCH 2 IBL 3 TCA 4 HAMMER 5 DELAY OPN 6 2P 4P 7 PREALL 8 BLOCK 9 S TW 10 U P DL1 DL13 SWC2 DL12 SWO2 DL11 SWC1 DL10 SWO1 DL9 BAR DL8 PHOT DL7 STOP DL6 CLOSE DL5 OPEN DL4 PED DL3 START E DL2 DL15 M2 DL16 DL14 START I 3 12 4 5 6 7 8 9 10 11 13 22 14 15 16 17 18 19 20...

Страница 14: ...aina flessibile Available couplings connecting the pipes to the box CRTR coupling with rigid pipe CRTL coupling with flexible sheath Disponibilité de raccords tube boîte CRTR raccord avec tube rigide CRTL raccord avec tuyau souple Erhältliche Rohrverschraubungen für Steuerungsgehäuse CRTR Verbindungsstück für starres Rohr CRTL Verbindungsstück für flexibles Rohr Disponibilidad de uniones tubo caja...

Страница 15: ...RIGEL 4 15 www metalines com sales metalines com ...

Страница 16: ...16 RIGEL 4 www metalines com sales metalines com ...

Отзывы: