INSTALLER WARNINGS

Anything that is not explicitly provided for in the installation ma-

nual is not allowed. The operator’s proper operation can only be 

guaranteed if the information given is complied with. The Firm shall 

not be answerable for damage caused by failure to comply with the 

instructions featured herein.

While we will not alter the product’s essential features, the Firm reserves 

the right, at any time, to make those changes deemed opportune to 

improve the product from a technical, design or commercial point of 

view, and will not be required to update this publication accordingly.

WARNING! Important safety instructions. Carefully read and comply with 

all the warnings and instructions that come with the product as incorrect 

installation can cause injury to people and animals and damage to property. 

The warnings and instructions give important information regarding safety, 

installation, use and maintenance. Keep hold of instructions so that you can 

attach them to the technical file and keep them handy for future reference.
GENERAL SAFETY

This product has been designed and built solely for the purpose indicated herein. 

Uses other than those indicated herein might cause damage to the product and 

create a hazard.

- The units making up the machine and its installation must meet the requirements 

of the following European Directives, where applicable: 2004/108/EC, 2006/95/

EC, 2006/42/EC, 89/106/EC, 99/05/EC and later amendments. For all countries 

outside the EEC, it is advisable to comply with the standards mentioned, in ad-

dition to any national standards in force, to achieve a good level of safety.

- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims 

all responsibility resulting from improper use or any use other than that for 

which the product has been designed, as indicated herein, as well as for failure 

to apply Good Practice in the construction of entry systems (doors, gates, etc.) 

and for deformation that could occur during use.

- Installation must be carried out by qualified personnel (professional installer, 

according to EN 12635), in compliance with Good Practice and current code.

- Before installing the product, make all structural changes required to produce 

safety gaps and to provide protection from or isolate all crushing, shearing and 

dragging hazard areas and danger zones in general in accordance with the 

provisions of standards EN 12604 and 12453 or any local installation standards. 

Check that the existing structure meets the necessary strength and stability 

requirements.

- Before commencing installation, check the product for damage.

- The Firm is not responsible for failure to apply Good Practice in the construction 

and maintenance of the doors, gates, etc. to be motorized, or for deformation 

that might occur during use. 

- Make sure the stated temperature range is compatible with the site in which the 

automated system is due to be installed.

- Do not install this product in an explosive atmosphere: the presence of flammable 

fumes or gas constitutes a serious safety hazard.

- Disconnect the electricity supply before performing any work on the system. 

Also disconnect buffer batteries, if any are connected.

- Before connecting the power supply, make sure the product’s ratings match the 

mains ratings and that a suitable residual current circuit breaker and overcurrent 

protection device have been installed upline from the electrical system. Have 

the automated system’s mains power supply fitted with a switch or omnipolar 

thermal-magnetic circuit breaker with a contact separation that provide full 

disconnection under overvoltage category III conditions.

- Make sure that upline from the mains power supply there is a residual current 

circuit breaker that trips at no more than 0.03A as well as any other equipment 

required by code.

- Make sure the earth system has been installed correctly: earth all the metal parts 

belonging to the entry system (doors, gates, etc.) and all parts of the system 

featuring an earth terminal.

- Installation must be carried out using safety devices and controls that meet 

standards EN 12978 and EN 12453.

- Impact forces can be reduced by using deformable edges.

- In the event impact forces exceed the values laid down by the relevant standards, 

apply electro-sensitive or pressure-sensitive devices.

- Apply all safety devices (photocells, safety edges, etc.) required to keep the 

area free of impact, crushing, dragging and shearing hazards. Bear in mind the 

standards and directives in force, Good Practice criteria, intended use, the instal-

lation environment, the operating logic of the system and forces generated by 

the automated system.

- Apply all signs required by current code to identify hazardous areas (residual 

risks). All installations must be visibly identified in compliance with the provisions 

of standard EN 13241-1.

Once installation is complete, apply a nameplate featuring the door/gate’s data.

- This product cannot be installed on leaves incorporating doors (unless the motor 

can be activated only when the door is closed).

- If the automated system is installed at a height of less than 2.5 m or is accessible, 

the electrical and mechanical parts must be suitably protected.

- For roller shutter automation only

  1) The motor’s moving parts must be installed at a height greater than 2.5 m 

above the floor or other surface from which they may be reached.

  2) The gearmotor must be installed in a segregated and suitably protected space 

so that it cannot be reached without the aid of tools.

- Install any fixed controls in a position where they will not cause a hazard, away 

from moving parts. More specifically, hold-to-run controls must be positioned 

within direct sight of the part being controlled and, unless they are key operated, 

must be installed at a height of at least 1.5 m and in a place where they cannot 

be reached by the public.

- Apply at least one warning light (flashing light) in a visible position, and also 

attach a Warning sign to the structure. 

- Attach a label near the operating device, in a permanent fashion, with informa-

tion on how to operate the automated system’s manual release.

- Make sure that, during operation, mechanical risks are avoided or relevant 

protective measures taken and, more specifically, that nothing can be banged, 

crushed, caught or cut between the part being operated and surrounding parts.

- Once installation is complete, make sure the motor automation settings are 

correct and that the safety and release systems are working properly.

- Only use original spare parts for any maintenance or repair work. The Firm dis-

claims all responsibility for the correct operation and safety of the automated 

system if parts from other manufacturers are used.

- Do not make any modifications to the automated system’s components unless 

explicitly authorized by the Firm.

- Instruct the system’s user on what residual risks may be encountered, on the 

control systems that have been applied and on how to open the system manu-

ally in an emergency. give the user guide to the end user.

- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accord-

ance with the provisions of the laws in force. Keep nylon bags and polystyrene 

out of reach of children.

WIRING

WARNING! 

For connection to the mains power supply, use: a multicore cable with 

a cross-sectional area of at least 5x1.5mm

2

 or 4x1.5mm

2

 when dealing with three-

phase power supplies or 3x1.5mm

2

 for single-phase supplies (by way of example, 

type H05RN-F cable can be used with a cross-sectional area of 4x1.5mm

2

). To con-

nect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm

2

.

-  Only use pushbuttons with a capacity of 10A-250V or more.

-  Wires must be secured with additional fastening near the terminals (for example, 

using cable clamps) in order to keep live parts well separated from safety extra 

low voltage parts.

-  During installation, the power cable must be stripped to allow the earth wire 

to be connected to the relevant terminal, while leaving the live wires as short 

as possible.  The earth wire must be the last to be pulled taut in the event the 

cable’s fastening device comes loose.

WARNING!

 safety extra low voltage wires must be kept physically separate from 

low voltage wires.

Only qualified personnel (professional installer) should be allowed to access 

live parts.

CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE

Before the automated system is finally put into operation, and during maintenance 

work, perform the following checks meticulously:

- Make sure all components are fastened securely.

- Check starting and stopping operations in the case of manual control.

- Check the logic for normal or personalized operation.

- For sliding gates only: check that the rack and pinion mesh correctly with 2 mm 

of play along the full length of the rack; keep the track the gate slides on clean 

and free of debris at all times.

- For sliding gates and doors only: make sure the gate’s running track is straight 

and horizontal and that the wheels are strong enough to take the weight of the 

gate.

- For cantilever sliding gates only: make sure there is no dipping or swinging 

during operation.

- For swing gates only: make sure the leaves’ axis of rotation is perfectly vertical.

-For barriers only: before opening the door, the spring must be decompressed 

(vertical boom).

- Check that all safety devices (photocells, safety edges, etc.) are working properly 

and that the anti-crush safety device is set correctly, making sure that the force 

of impact measured at the points provided for by standard EN 12445 is lower 

than the value laid down by standard EN 12453.

- Impact forces can be reduced by using deformable edges.

- Make sure that the emergency operation works, where this feature is provided.

- Check opening and closing operations with the control devices applied.

- Check that electrical connections and cabling are intact, making extra sure that 

insulating sheaths and cable glands are undamaged.

- While performing maintenance, clean the photocells’ optics.

- When the automated system is out of service for any length of time, activate the 

emergency release (see “EMERGENCY OPERATION” section) so that the operated 

part is made idle, thus allowing the gate to be opened and closed manually.

- If the power cord is damaged, it must be replaced by the manufacturer or their 

technical assistance department or other such qualified person to avoid any risk .

- If “D” type devices are installed (as defined by EN12453), connect in unverified 

mode, foresee mandatory maintenance at least every six months

- The maintenance described above must be repeated at least once yearly or at 

shorter intervals where site or installation conditions make this necessary.

WARNING! 

Remember that the drive is designed to make the gate/door easier to use and 

will not solve problems as a result of defective or poorly performed installation 

or lack of maintenance

  

SCRAPPING

   

Materials must be disposed of in accordance with the regulations in 

force. Do not throw away your discarded equipment or used batteries 

with household waste. You are responsible for taking all your waste 

electrical and electronic equipment to a suitable recycling centre.

DISMANTLING

If the automated system is being dismantled in order to be reassembled at another 

site, you are required to:

- Cut off the power and disconnect the whole electrical system.

- Remove the actuator from the base it is mounted on.

- Remove all the installation’s components.

- See to the replacement of any components that cannot be removed or happen 

to be damaged.

 

D811766_15

ORO - ORO E- 

3

D811247_05

Содержание ORO

Страница 1: ...TORE AUTOMATIZACIONES A PISTON PARA PORTONES CON BATIENTE AUTOMATIZAÇÕES DE PISTÃO PARA PORTÕES DE BATENTE Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las Advertencias en el i...

Страница 2: ...tofthepartbeingcontrolledand unlesstheyarekeyoperated must be installed at a height of at least 1 5 m and in a place where they cannot be reached by the public Apply at least one warning light flashing light in a visible position and also attach a Warning sign to the structure Attach a label near the operating device in a permanent fashion with informa tion on how to operate the automated system s...

Страница 3: ...ock has not been relea sed by means of the appropriate key In mod ORO the release has not been activated by means of the appropriate key fig 1 2 EMERGENCY MANOEUVRE 2 1 Mod ORO In case of emergency for example when the electrical power is disconnected to release the gate insert the same key C used for the adjustment of the by pass val ve inside the triangular pin Fig 1 and rotate it counter clockw...

Страница 4: ... 1 Mod ORO En casos de emergencia por ejemplo cuando falta el suministro de corriente para desbloquear la cancela hay que introducir la llave C utilizada para la regula ción de la válvula by pass en el perno triangular fig 1 y girarla en sentido contrario a las agujas del reloj La cancela de esta manera se puede abrir manual mente Para restablecer el funcionamiento eléctrico del servomotor habrá q...

Страница 5: ...b Carrera total Cu Corsa utile Working stroke Course utile Nutzhub Carrera útil a mm b mm 630 890 950 5 80 64 75 5 70 64 70 5 104 99 94 91 112 99 94 91 88 105 94 91 100 89 87 95 95 95 103 90 90 89 86 96 106 84 α 89 80 97 83 88 80 90 100 110 120 130 140 150 160 80 90 100 110 120 130 140 150 160 16 ORO ORO E D811247_05 ...

Страница 6: ...28 ORO Ver 03 Fig 4 Fig 6 Fig 5 Fig 8 Fig 7 45 a b Min 1000 b 40 b 5 5 b kg C a P D F b x Z b x 40mm F ORO ORO E 17 D811247_05 ...

Страница 7: ...ORO Ver 03 29 Fig 11 Fig 12 Fig 10 Fig 9 Fig 8A P L Z a b c a b c PF F F F T PF F 7 18 ORO ORO E D811247_05 ...

Страница 8: ... 262 T 11 Close Open EBP FA FA FA x D x S E S P I R Q M M AL 2 2 2 3x1mm 2x1 5mm 2 2 2 4x1mm 2 4x1 5mm 3x1mm 2x1mm Fte 2x1 5mm RG58 2 2 2x1mm 2 2 3x1 5mm Fti CF CF Fri 4x1mm 4x1 5mm ORO ORO E 5 D811247_04 ORO ORO E 19 D811247_05 ...

Страница 9: ...ORO Ver 03 31 Fig 19 Fig 18 Fig 17 a b S C CLOSE OPEN 20 ORO ORO E D811247_05 ...

Страница 10: ...RELAND BFT AUTOMATION LTD Dublin 12 BENELUX BFT BENELUX SA 1400 Nivelles www bftbenelux be POLAND BFT POLSKA SP Z O O 05 091 ZĄBKI www bft pl CROATIA BFT ADRIA D O O 51218 Drazice Rijeka www bft hr PORTUGAL BFT SA COMERCIO DE AUTOMATISMOS E MATERIAL DE SEGURANCIA 3020 305 Coimbra www bftportugal com CZECH REPUBLIC BFT CZ S R O Praha www bft it TURKEY BFT OTOMATIK KAPI SISTEMELERI SANAY VE Istanbul...

Страница 11: ...s requirements and type of operation They are models available with a hydraulic lock on closing or without a hydraulic lock in which an electric lock is required To make the manual manoeuvre easier the lock can be released by means of a triangular pin which can be reached using the appropriate key The pushing force is adjusted with extreme precision by means of two by pass valves which provide ant...

Страница 12: ...opriate key To make the manual manoeuvre easier the lock can be released by means of a triangular pin which can be reached using the appropriate key 10 PUSHING FORCE ADJUSTMENT The pushing force is adjusted by two valves marked with the writing Close and Open respectively which are used to adjust the closing and opening pushing force fig 19 Lift open the lid indicated in Fig 19 there you will find...

Страница 13: ... usly rate ices ntrol of a ently rom tion netic and ation ncy the Leaf stops when the operation time is insufficient the leaves may not complete their strokes In that case slightly increase the operation time setting in the control unit 16 2 Faulty operation of the electrical accessories All faulty control and safety devices can cause abnormal operation or automation block If the control unit is p...

Страница 14: ...ITALY ...

Отзывы: