background image

448

D811230_04

TRIMMER T2 BRAKE

: Controls the braking couple.

ATTENTION -

 The trimmer braking effect is set by the manufacturer during

testing and is then sealed. If the trimmer needs recalibrating, please take
note of the following:
a) Braking should not be sudden.
b) Braking which is too weak creates slippage due to inertia.

Braking can be increased by turning it clockwise.

7) LED FUNCTIONS 

(Fig.1)

7.1) BOARD ORION G
1 - START

Lights up upon start impulse.

2 - STOP

Turns off upon opening of the block contact.

3 - PHOTOCELL

Turns  off  if  photoelectric  cells  are  not  aligned  or  if  there  are  obstacles
interfering with the cells.

4 - OPENING LIMIT SWITCH

Turns off in a full open position.

5 - CLOSING LIMIT SWITCH

Turns off in a full closed position.

6 - OPENS

Turns on during the motor opening phase.

7 - CLOSES

Turns on during the motor closing phase.

8 - MAINS SUPPLY

Turns on when there is power and when the fuses are integral.

SOG optional board
9 - OPENS

Turns on at the 

hold-to-run

 open command.

10 - CLOSES

Turns on at the 

hold-to-run

 close command.

11 - RUBBER SKIRT ALARM

Turns on when the rubber or infrared safety skirts is activated.

12 - PEDESTRIAN

Turns on at the pedestrian opening command.

8) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified
personnel regularly.

 The materials making up the set and its packing must

be disposed of according to the regulations in force. 

Batteries must be

properly disposed of.

The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement  of  the  product,  while  leaving  the  essential  product
features unchanged, at any time and without undertaking to update
the present publication.

ORION G-GBR

ORION G-GBR

CONTROL UNITS

CONTROL UNITS

Отзывы: