STOP
FCC
Control unit
m
6.4
if
j;f,fi :
■
INPUTS TERMINAL BLOCK
2 wire N.O. closing limit switch input (set parameter
LI:=
□□-
level 3
and parameterFC=
□
I- level 2).
When activated the opening travel ends
(XPASS B S00C).
3
wire N.O. closing limit switch input (set parameter
LI:=
00
- level 3
and parameter
FC
=
0
I - level 2).
When activated the opening travel ends
(XPASS B 1200C) .
FCA
2 wire N.O. opening limit switch input (set parameter
LI::=
□□-
level 3). When activated the opening travel
ends.
3 wire N.O. opening limit switch input (set parameter
LI:=
□
I- level 3). When activated the opening travel
ends
(XPASS B 1200C) .
N.C. safety input. When it is activated, the automation is immediately stopped. During the pause time, a stop control eliminates
the automatic closing, leaving the bollard open waiting for a command.
FTC
N.C. photocell input. It allows the automation to be closed only if the safety devices have not triggered. Operating mode
programmable with parameter Fl::-level 1.
CLOSE
N.O. closing input. It allows the automation to be closed only if the safety devices have not triggered. Operating mode pro
grammable with parameter CL-level 1.
OPEN
N.O. opening input.
By keeping this input controlled, the automation performs the opening manoeuvre and will close automatically only when the
input is freed. Connect clocks, daily timers or weekly timers here if wanted.
START
N.O. input that operates the bollard's opening and closing. The command is ignored while opening
PDM
Programmable Input Pd-3
°
1iv ..
May be duplicated on AUX output.
PRES 1
Closure travel limit pressure switch input
(see parameter
PP-
level 3). Limit switch N.C. input in closing.
When activated the closing travel finishes (For hydraulic bollards only).
PRES2
ECO pressure switch input
(see parameter
PE-
level 3
and parameter
EF-
level 2).
(For ECO equipped bollards only).
UPS
UPS status input. To be connected to smart UPS with status output, active-high during mains failure. The control unit has also
an internal detector that works with simpler square-wave and quasi-sinusosidal UPS. With these simpler UPS there is no need
to use this input.
�
AUXILIARY INPUT AUX
u
<
For bollards with ECO device. ls active when emergency ECO command is active
(see parameter
PF-
level 3)
'"'lJ
Q
z
.,
<
:i:
0
ANALOG INPUT
Multi-purpose analog input O .. SV
ANTENNA
Antenna connection for the radio receiver (option).