Control unit
m
• [ L: Close configuration
-
D
I: Close-when-released input
The bollard closes automatically only when the vehicle has completely passed by the photocell or magnetic detector (the recom
mended accessories for this purpose). Connect the N.O. contact of the detector or photocell to the close input terminals.
If the vehicle is on the detector or in front of the photocell it does not cause immediate closing but the control board will wait for
the signal to be released (i.e. vehicle moved).
- 02: The close command acts as close-when-released and safety function.
When closing, a close command stops the automation. When close input becomes inactive the bollard resumes closing.
-Pr: Preset
-To configure the parameters for installation type
A, B,
C and
D;
set the corresponding value and exit the menu. See chapter 13 for
details on installation types.
•
dF:
Default
- To restore the parameters to the factory default values, set the"DF" to 1 or 2, then exit the menu. if PF=
□
2 the communication
"Com" settings is are kept.
Warning:The"default" operation sets all parameters to the factory default values, including the Preset values and the bollard type.
8.3
2nd LEVEL
PROGRAMMING
The following table gives the 2nd level functions and the adjustable parameters.
�- DEFAULT I
t • f t
,.e.
..._
= parameter value set during installation: should be filled if DE-
-
va ue se in ac ory.
IA\ FAULT value is modified.
Par
Function
Settable data
�
ti\
00: disabled
Sr
Request for maintenance
0
I: active on the configured outputs
00
02: as in
O
I plus lights flash twice
nt
Programming maintenance cycles 00-99
00
in thousands
nl
Programming maintenance
0.0-9.9
0.0
cycles in millions
00: scheduled maintenance required
0
I: photocell triggering
02: obstacle detection (for hydraulic bollard only)
03: PDM input active
OY: bollard fully up (close position)
05: bollard fully down (open position)
�
06: STOP input active
I I
01: warning flash
0
oY
OB: START input active
oS
Output 4, Output 5
09: OPEN input active
10: power failure (the output is activated at switch-on)
I I: assistance required
I I
12: CLOSE input active
0
13: UPS
IY: second radio channel active
15: buzzer (for Totem)
16: ECD pressure switch failure
11: FCC sensor failure or manual forcing attempt
F[
Closing limit switch presence
0: not present
see
0
I: present
note
EF
ECD present (for SD version and 00: not present
00
XPASS B 1200C)
0
I: present
tE
TERMON
00-30: heating level (0 I= min; 30 = max)
00
- 31-