Control unit
m
13.3
INSTALLATION C
CONTROLLED ENTRY AND EXIT
This solution is recommended when you want to enter a reserved area in both directions by activating a command (radio control, proximity
key, magnetic keys, etc.).
ENTRY
2
-
=-
The vehicle approaches the reserved
area.
When the vehicle is over loop
S1
the bollard will go down only after a
command (ex.: remote control).
If the device is rising and the user
wants to lower it again, the vehicle
must be over loop
S1
and the com
mand must be repeated.
When the vehicle is no longer over
loop
S2,
the bollard will go up
automatically after an adjustable
pause time.
The vehicle approaches the reserved
area.
When the vehicle is over loop
S2,
the bollard will go down only after a
command (ex.: remote control).
If the bollard is rising and the user
wants to lower it again, the vehicle
must be over loop
S2
and the com
mand must be repeated.
When the vehicle leaves
loop
S1
the bollard will
rise automatically af
ter an adjustable pause
time.
Loops 51 and 52 also have a safety function in that they will not let the bollard to move all the time if the vehicle is over 51 or 52.
RECOMMENDED
DIMENSIONS
- Connect the
N.O.
contact of the coil
S1
and
S2
receiver to
PDM
input.
- The dimensional values given are approximate.
*
We suggest installing the
"RME 2"
metal mass detector.
PARAMETER
lo
t:P
:r
FP
II
r /
,:i
[P
[L
- 39 -
DATA DESCRIPTION
02
Functioning logic: Automatic
/-99
Pause time
02
Opening consent and pause time reset
02
Radio channel 1: Open
00
Command during pause is OFF
00
Standard close