Control unit
EN
- 28 -
9.4
3RD
LEVEL PROGRAMMING
The following table gives the 3rd level functions and the single parameters.
= DEFAULT value set in factory.
= parameter value set during installation: must be indicated if DEFAULT value is modifi ed.
NOTES:
·
,
,
,
:
Output polarity
Output polarity: The outputs can be confi gured as N.O. or N.C. but, in the event of a blackout the contacts open anyway.
·
:
Velocity selection input
By enabling this parameter bar speed can be adjusted via the PDM input
(
)
, or it is possible manages the color of the cap for report the free
seats in the parking systems
(
).
If the PDM is activated and parameter
enabled the barrier moves at a speed equal to 60% of maximum speed, both when opening and
closing.
The PDM manages the RED/GREEN color of the cap and report the free seats in the parking systems (see paragraph 10)
·
:
Advance electric lock disengagement
This parameter adjusts the delay between electo-lock deactivation and engine start , to allow the resetting of the residual magnetism of the
electro lock.
·
:
Advanced setup
This parameter enables the use of special confi gurations for specifi c necessities.
N/A.
Controlled entry and automatic exit (see paragraph 13).
·
: UPS
UPS TYPE
Square-wave
Internal detector, UPS input not connected
UPS with sinusoidal or quasi-sinusoidal wave form,
with
dedicated output for signaling the absence of power net
Connect mains failure output to UPS input
Pure-sinusoidal wave UPS
with
dedicated output for signaling
the absence of power net
Use 230Vac relais, coil connected to mains supply, close contacts to UPS input
·
Boom locking device confi guration:
To use the boom locking device, connect the enabling contact to OUT2 or OUT3 or OUT4 or OUT5 and set the corresponding
parameter
,
,
or
to
. Set advance electric lock disengagement (
-3nd level)
Par
Function
Settable data
Advanced setup
(see notes after the table)
: no advanced setup
: N/A
: controlled entry and automatic exit
PDM dynamic input polarity
: input N.O.
: input N.C.
Output 2 polarity
Output 3 polarity
Output 4 polarity
Output 5 polarity
(see notes after the table)
: N.O.
: N.C.
Advance electric lock
disengagement
(see notes after the table)
: 0,5s -
: 1s -
: 1,5s -
: 2s -
: 2,5s -
: 3s
Opening speed (%)
-
(ATM 90°, ATM 180°)
-
(MAXIMA ULTRA 35, Carbon)
-
(MAXIMA ULTRA 68)
Closing speed (%)
-
(MAXIMA ULTRA 68, ATM 90°, ATM 180°)
-
(MAXIMA ULTRA 35, Carbon)
Speed selection input
(see notes after the table)
: Disabled
: Enabled
: MAXIMA ULTRA 36 cap lights for parking function
Swinging boom sensor input
(see notes after the table)
: swinging boom not mounted or disabled
: swinging boom sensor mounted and activated N.C.
Exiting the menu/saving
Pressing the “F” key, the programming menu is quit and the changes saved.
ENGLISH