background image

ARIES/ARIES-P - Ver. 04 -

13

D811184A_04

INSTALLATION MANUAL

ENGLISH

DIP4 Automatic closing time (TCA)

ON: Automatic closing activated (can be adjusted from 0 to 90s).

OFF: Automatic closing not activated.

DIP5 Control logic

ON: 2-step logic is activated (see start paragraph).

OFF: 4-step logic is activated (see start paragraph).

DIP6: Preallarm (mod.ARIES P only)

ON: The flashing light turns on abt 3 seconds before the motors start.

OFF The flashing light turns on simultaneously with the start of the motors.

ATTENTION:

Dip non used in mod. 

ARIES

 (always in OFF set).

7) TRIMMER ADJUSTMENT
TCA

  This  adjusts  the  automatic  closing  time,  after  which  time  the  gate

automatically closes (can be adjusted from 0 to 90s).

TW

This adjusts the motor working time, after which time the motor stops

(can be adjusted from 0 to 40s).

TDELAY

 This adjusts the closing delay time of the second motor (M2).

8) MOTOR TORQUE ADJUSTMENT

The

ARIES

  control  unit  has  electric  torque  adjustment  which  allows  the

motor force to be adjusted.

The adjustment should be set for the minimum force required to carry out

the opening and closing strokes completely.

Adjustment is carried out by moving the connection 55 (fig.3) on the tran-

sformer sockets as described below:

Pos.T1 1st TORQUE (MINIMUM TORQUE)

Pos.T2 2nd TORQUE

Pos.T3 3rd TORQUE

Pos.T4 4th TORQUE (MAXIMUM TORQUE)

4 motor torque values can be obtained.

To  gain  access  to  the  torque  adjustment  sockets,  disconnect  the  mains

supply and remove the protective case 

P

 of the transfomer.

CAUTION:

 Excessive torque adjustment may jeopardise the anti-squash

safety function. On the other hand insufficient torque adjustment may not

guarantee correct opening or closing strokes.

9) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified
personnel regularly.

 The materials making up the set and its packing must

be disposed of according to the regulations in force.

Batteries must be properly disposed of.

WARNINGS
Correct controller operation is only ensured when the data contained
in the present manual are observed. The company is not to be held
responsible for any damage resulting from failure to observe the
installation  standards and  the  instructions  contained  in  the
present manual.

The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement  of  the  product,  while  leaving  the  essential  product
features unchanged, at any time and without undertaking to update
the present publication.

Содержание ARIES

Страница 1: ...ET D INSTALLATION INSTALLATIONS UND GEBRAUCHSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION INSTRUÇÕES DE USO E DE INSTALAÇÃO CENTRALINA DI COMANDO D811184A ver 04 08 02 02 I CONTROL UNIT GB UNITÉ DE COMMANDE F STEUERZENTRALE D CENTRAL DE MANDO E CENTRAL DO MANDO P ARIES ARIES P 8 027908 113740 ...

Страница 2: ...ARIES ARIES P Ver 04 3 D811184A_04 ...

Страница 3: ...tocells only activated during closing OFF Photocells activated during opening and closing Automatic closing time TCA ON Automatic closing activated can be adjusted from 0 to 90s Preallarm mod ARIES P only ON The flashing light turns on abt 3 seconds before the motors start FOR THE INSTALLER check the boxes you are interested in START four step logic Gate closed Gate open During opening During clos...

Страница 4: ...ontrol devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed 3 TECHNICAL SPECIFICATIONS Power supply 230V 10 50Hz Absorption on empty 0 5A...

Страница 5: ... sockets as described below Pos T1 1st TORQUE MINIMUM TORQUE Pos T2 2nd TORQUE Pos T3 3rd TORQUE Pos T4 4th TORQUE MAXIMUM TORQUE 4 motor torque values can be obtained To gain access to the torque adjustment sockets disconnect the mains supply and remove the protective case P of the transfomer CAUTION Excessive torque adjustment may jeopardise the anti squash safety function On the other hand insu...

Страница 6: ... JP4 JP12 MOT1 MOT2 JP13 M1 M2 r JP14 JP15 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MAX40W JP4 JP2 JP12 MOT1 MOT2 JP13 M1 M2 r JP14 JP15 7 8 9 10 11 12 COMM START STOP PHOT NO NO NO II CH NC NC 0V SCA 24Vac COMM ANTEN 13 14 15 16 17 18 19 20 21 22 23 25 26 JP2 NO II CH 25 26 COMM START STOP PHOT NO NC NC 0V SCA 24Vac COMM PED ANTEN ...

Страница 7: ...LOS CONDENSADORES EN LA CENTRAL DE MANDO LIGA ÍE CONDENSADORES NA CENTRAL DE MANDO JP12 JP4 TW TCA DL1 66 55 44 TDELAY MOT1 MOT2 JP13 M1 M2 r JP14 JP15 5 6 7 23 22 21 20 19 26 25 II CH 18 17 16 15 14 13 JP4 11 12 10 9 8 7 6 5 JP3 JP11 JP6 JP7 2 T 0 5A 230V T 1A 110V T 2 5A 230V T 5A 110V 1 JP5 JP13 JP12 JP9 JP14 JP15 L 0V 0 12 12 T2 T3 T4 N 22 11 33 JP8 JP10 JP2 55 P 8 9 10 11 12 ON 1 2 3 4 5 6 DI...

Отзывы: