ARIES/ARIES-P - Ver. 04 -

 5

D811184A_04

USER’S MANUAL

ENGLISH

Thank you for buying this product, our company is sure that you will be more than satisfied with the product

s performance. The product is supplied with

a

WARNINGS

 leaflet and an 

INSTRUCTION MANUAL

.

These should both be read carefully as they provide important information about safety, installation, operation and maintenance. This product complies

with the recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives:

 89/336/EEC and 73/23/EEC (and subsequent amendments).

1) GENERAL OUTLINE

The

ARIES

 control unit has been designed for swing gates. It can be used for one or two gate controllers.

The control unit mod. ARIES P can also be used to perform opening of a single actuator while keeping the other one closed (pedestrian access).

2) FUNCTIONS

STOP:

 In all cases: it stops the gate until a new start command is given.

PHOT:

Functions can be set with Dip-Switch.

Activated during closing.

Activated during opening and closing.

Rapid closing

 ON: When the position of the gate photocells is exceeded, during both opening and closing, the gate automatically starts to close even if TCA is

activated. We recommend setting DIP3 to ON (photocells only activated during closing).

Blocks impulses

 ON: During opening, START commands are not accepted.

 OFF: During opening, START commands are accepted.

Photocells

 ON: Photocells only activated during closing.

 OFF: Photocells activated during opening and closing.

Automatic closing time (TCA)

 ON: Automatic closing activated (can be adjusted from 0 to 90s)

Preallarm (mod. ARIES P only)

 ON: The flashing light turns on abt 3 seconds before the motors start.

FOR THE INSTALLER:

 check the boxes you are interested in.

START: four-step logic

Gate closed

Gate open

During opening

During closing

After stop

START: two-step logic

SCA: Gate open indicating light

it opens

it opens

it stops and activates TCA

it closes

it stops and does not activate TCA

 it starts opening

it stops and activats TCA (if activated)

it closes

it opens

it opens

off

on

on

 flashing

ATTENTION:

Dip non used in mod. 

ARIES

 (always in OFF set).

3) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified personnel regularly.

 The materials making up the set and its packing must

be disposed of according to the regulations in force.

Batteries must be properly disposed of.

WARNINGS
Correct controller operation is only ensured when the data contained in the present manual are observed. The company is not to be held
responsible for any damage resulting from failure to observe the installation standards and the instructions contained in the present
manual.

The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features
unchanged, at any time and without undertaking to update the present publication.

Содержание ARIES

Страница 1: ...ET D INSTALLATION INSTALLATIONS UND GEBRAUCHSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION INSTRUÇÕES DE USO E DE INSTALAÇÃO CENTRALINA DI COMANDO D811184A ver 04 08 02 02 I CONTROL UNIT GB UNITÉ DE COMMANDE F STEUERZENTRALE D CENTRAL DE MANDO E CENTRAL DO MANDO P ARIES ARIES P 8 027908 113740 ...

Страница 2: ...ARIES ARIES P Ver 04 3 D811184A_04 ...

Страница 3: ...tocells only activated during closing OFF Photocells activated during opening and closing Automatic closing time TCA ON Automatic closing activated can be adjusted from 0 to 90s Preallarm mod ARIES P only ON The flashing light turns on abt 3 seconds before the motors start FOR THE INSTALLER check the boxes you are interested in START four step logic Gate closed Gate open During opening During clos...

Страница 4: ...ontrol devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed 3 TECHNICAL SPECIFICATIONS Power supply 230V 10 50Hz Absorption on empty 0 5A...

Страница 5: ... sockets as described below Pos T1 1st TORQUE MINIMUM TORQUE Pos T2 2nd TORQUE Pos T3 3rd TORQUE Pos T4 4th TORQUE MAXIMUM TORQUE 4 motor torque values can be obtained To gain access to the torque adjustment sockets disconnect the mains supply and remove the protective case P of the transfomer CAUTION Excessive torque adjustment may jeopardise the anti squash safety function On the other hand insu...

Страница 6: ... JP4 JP12 MOT1 MOT2 JP13 M1 M2 r JP14 JP15 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 MAX40W JP4 JP2 JP12 MOT1 MOT2 JP13 M1 M2 r JP14 JP15 7 8 9 10 11 12 COMM START STOP PHOT NO NO NO II CH NC NC 0V SCA 24Vac COMM ANTEN 13 14 15 16 17 18 19 20 21 22 23 25 26 JP2 NO II CH 25 26 COMM START STOP PHOT NO NC NC 0V SCA 24Vac COMM PED ANTEN ...

Страница 7: ...LOS CONDENSADORES EN LA CENTRAL DE MANDO LIGA ÍE CONDENSADORES NA CENTRAL DE MANDO JP12 JP4 TW TCA DL1 66 55 44 TDELAY MOT1 MOT2 JP13 M1 M2 r JP14 JP15 5 6 7 23 22 21 20 19 26 25 II CH 18 17 16 15 14 13 JP4 11 12 10 9 8 7 6 5 JP3 JP11 JP6 JP7 2 T 0 5A 230V T 1A 110V T 2 5A 230V T 5A 110V 1 JP5 JP13 JP12 JP9 JP14 JP15 L 0V 0 12 12 T2 T3 T4 N 22 11 33 JP8 JP10 JP2 55 P 8 9 10 11 12 ON 1 2 3 4 5 6 DI...

Отзывы: